Key result
TEE-guided transseptal ablation achieves complete pulmonary vein isolation and 12-month AF freedom despite a septal occluder.
Why the study?
Catheter ablation for AF poses technical difficulties and complication risks regarding left atrial access in patients with prior percutaneous ASD closure.
Is catheter AF ablation using a single transeptal approach guided by TEE feasible and safe in a patient with prior percutaneous ASD closure?
Case Report (n=1)
No
Is catheter AF ablation using a single transeptal approach guided by TEE feasible and safe in a patient with prior percutaneous ASD closure?
A single transeptal approach guided by TEE is a feasible and safe strategy for AF ablation in patients with prior percutaneous ASD closure.
Answers are grounded in this paper and cite their sources.
May support TEE-guided single-transseptal AF ablation after ASD closure in select cases; leaves open need for prospective validation.
Background: Atrial septal defect (ASD) is associated with a risk of developing atrial fibrillation (AF) higher than in the general population, even after percutaneous or surgical septal closure. Catheter ablation is an effective treatment strategy for preventing recurrences and reducing the AF burden. However, electrophysiologists are faced with technical difficulties and the risk of complications with the left atrium access in patients with prior ASD percutaneous closure. Case summary: We report a case of a patient with highly symptomatic paroxysmal AF, with an ASD, closed percutaneously many years before, who underwent a successful catheter AF ablation, using a single transeptal (TSP) approach guided by transesophageal echocardiography (TEE). Discussion: In patients with ASD and an occluder device implanted, there is a potential risk for septal tear during the TSP passage, device dislodgement, or thrombus formation on the device. Atrial fibrillation ablation in this subset of patients has often been protracted and scarcely reported. TEE and intra-cardiac echocardiography have been increasingly used for interventional procedure guidance during AF ablation. As described here, AF ablation using a simplified single TSP guided by TEE is feasible, safe, and effective after device ASD closure.
No takes yet. Share an insight, caveat, or question.
Oliveira et al. (2023) conducted a case report in Paroxysmal atrial fibrillation with prior percutaneous atrial septal defect closure (n=1). Catheter ablation (pulmonary vein isolation) via a single transseptal puncture guided by transesophageal echocardiography was evaluated on Elimination of pulmonary vein potentials and freedom from atrial fibrillation at 12-month follow-up. TEE-guided single transseptal puncture catheter ablation achieved complete pulmonary vein isolation and 12-month freedom from AF without complications in a patient with a 26 mm septal occluder.
Synapse has enriched 10 related papers. Consider them for comparative context: