Key result
Transesophageal echocardiography successfully guided a double transseptal puncture for pulmonary vein isolation in a patient with a 30 mm atrial septal closure device without complications.
Case Report (n=1)
No
Describes a case of transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a large (30 mm) atrial septal closure device.
May facilitate AF ablation in patients with large ASD closure devices; hypothesis-generating and requires prospective validation.
ENWEndNote BIBJabRef, Mendeley RISPapers, Reference Manager, RefWorks, Zotero AMA Sabiniewicz R, Królak T, Woźniak L, Budrejko S, Raczak G. Transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a 30 mm atrial septal closure device. Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej. 2016;12(3):285-286. doi:10.5114/aic.2016.61658. APA Sabiniewicz, R., Królak, T., Woźniak, L., Budrejko, S., & Raczak, G. (2016). Transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a 30 mm atrial septal closure device. Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej, 12(3), 285-286. https://doi.org/10.5114/aic.2016.61658 Chicago Sabiniewicz, Robert, Tomasz Królak, Lidia Woźniak, Szymon Budrejko, and Grzegorz Raczak. 2016. "Transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a 30 mm atrial septal closure device". Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej 12 (3): 285-286. doi:10.5114/aic.2016.61658. Harvard Sabiniewicz, R., Królak, T., Woźniak, L., Budrejko, S., and Raczak, G. (2016). Transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a 30 mm atrial septal closure device. Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej, 12(3), pp.285-286. https://doi.org/10.5114/aic.2016.61658 MLA Sabiniewicz, Robert et al. "Transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a 30 mm atrial septal closure device." Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej, vol. 12, no. 3, 2016, pp. 285-286. doi:10.5114/aic.2016.61658. Vancouver Sabiniewicz R, Królak T, Woźniak L, Budrejko S, Raczak G. Transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a 30 mm atrial septal closure device. Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej. 2016;12(3):285-286. doi:10.5114/aic.2016.61658.
No takes yet. Share an insight, caveat, or question.
Sabiniewicz et al. (2016) conducted a case report in Drug-refractory atrial fibrillation with a prior patent foramen ovale closure device (n=1). Transesophageal echocardiography guided transseptal puncture was evaluated on Successful transseptal puncture and pulmonary vein isolation. Transesophageal echocardiography successfully guided a double transseptal puncture for pulmonary vein isolation in a patient with a 30 mm atrial septal closure device without complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: