Key result
Post-clinic systolic blood pressure readings (121 ± 21 mmHg) were lower than in-clinic readings.
Why the study?
Are blood pressure readings taken after a patient-physician encounter lower than those taken before or during the encounter?
Observational (n=180)
No
Are blood pressure readings taken after a patient-physician encounter lower than those taken before or during the encounter?
Blood pressure readings taken after a clinic encounter are significantly lower than in-clinic readings, suggesting in-clinic measurements may overestimate blood pressure.
Answers are grounded in this paper and cite their sources.
Post-clinic BP readings may be lower than in-clinic; hypothesis-generating for white-coat effect and requires prospective validation before practice change.
OBJECTIVE: To determine the difference in Blood Pressure (BP) readings taken before, during and after the clinic encounter. STUDY DESIGN: Descriptive study. PLACE AND DURATION OF STUDY: Cardiology Clinic, The Aga Khan University Hospital, Karachi, from January to August 2013. METHODOLOGY: Hypertensive and normotensive participants aged ³ 18 years were recruited. Pre-clinic BP was measured by a nurse and in-clinic BP by a physician. After 15 minutes, two post-clinic BP readings were taken at 1 minute interval. All readings were taken using Omron HEM7221-E. RESULTS: Out of 180 participants, males were 57% and 130 (71%) were hypertensive. Mean SBP (Systolic BP) taken preclinic, in-clinic, post-clinic 1 and post-clinic 2 were: 126 ± 20 mmHg, 131 ± 23 mmHg, 126 ± 20 mmHg and 121 ± 21 mmHg respectively (p < 0.001). Mean DBP (Diastolic BP) taken pre-clinic, in-clinic, post-clinic 1 and post-clinic 2 were 77 ± 12 mmHg, 81 ± 13 mmHg, 79 ± 12 mmHg and 79 ± 11 mmHg respectively (p < 0.001). CONCLUSION: BP taken in the post-clinic setting may significantly be the lowest reading in a clinic encounter, making in-clinic BP unreliable to diagnose or manage hypertension.
No takes yet. Share an insight, caveat, or question.
Shahab et al. (2015) conducted an observational in Hypertension (n=180). Post-clinic blood pressure measurement vs. In-clinic blood pressure measurement was evaluated on Systolic Blood Pressure (SBP) (p=< 0.001). Post-clinic systolic blood pressure readings (121 ± 21 mmHg) were lower than in-clinic readings.