Answers are grounded in this paper and cite their sources.
OBJECTIVE: A simple, precise, reliable, rapid, sensitive and validated RP-HPLC method has been developed to determine esomeprazole magnesium trihydrate (ESO) and naproxen (NAP) in synthetic mixture form. MATERIALS AND METHODS: Chromatographic separation achieved isocratically on Phenomenex, Luna C18 column (5 μm, 150mm × 4.60mm) and acetonitrile: phosphate buffer (pH 7.0) in the ratio of 50:50 (v/v) as the mobile phase, at a flow rate of 0.5 ml/min. Detection was carried out at 300 nm. The retention times for NAP and ESO was found to be 2.67 ±0.014 and 5.65 ±0.09 min respectively. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the ICH guidelines. RESULTS: The method was linear in the concentration range of 50-250 μg/ml for NAP and 2-10 μg/ml for ESO with correlation coefficient of 0.999 and 0.998 respectively. The mean recoveries obtained for NAP and ESO were 100.01% and 97.76 % respectively and RSD was less than 2. The correlation coefficients for all components are close to 1. CONCLUSIONS: Developed method was found to be accurate, precise, selective and rapid for simultaneous estimation of NAP and ESO.
No takes yet. Share an insight, caveat, or question.
Jain et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: