Answers are grounded in this paper and cite their sources.
This paper proposes an energy regeneration circuit for three-phase voltage-fed inverters using a modified Undeland snubber. The proposed system uses a quasi-square-wave zero voltage switching dc-dc auxiliary converter to regenerate the energy from snubber capacitor to the dc bus. The regenerative circuit uses a single active switch, and it operates independently of the three-phase inverter. Operation stages, theoretical waveforms, and a design methodology are presented. Experimental results based on a 4.5-kVA three-phase inverter prototype are included to validate the proposed topology.
No takes yet. Share an insight, caveat, or question.
Sperb et al. (2010) studied this question.