Answers are grounded in this paper and cite their sources.
We investigated the carrier lifetime and Z1/2 center density of thick n-type 4H-SiC epilayers, which were oxidized and subsequently annealed in Ar at high temperatures. The Z1/2 center density decreased below the detection limit in the region to, at least, a 130 µm depth by thermal oxidation. After subsequent high-temperature annealing, the Z1/2 center density increased with increasing annealing temperature, while the distribution of the Z1/2 center density was nearly uniform to a 130 µm depth. The carrier lifetime could be controlled from 26 to 2.4 µs by changing the annealing temperature from 1600 to 1800 °C.
No takes yet. Share an insight, caveat, or question.
Saito et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: