The correct choice of packing is of decisive importance for optimum process efficiency in the operation of two‐phase countercurrent columns. An important criterion for this choice is the pressure drop in the gas flow. Theoretical relationships are derived for calculating the pressure drop in beds with dry and trickle packings. It has been demonstrated by comprehensive experiments that these relationships allow the pressure drop to be determined more accurately than by previous methods. The experiments were performed at the Department of Thermal Separation Processes of Bochum University on 54 different packed beds, using 24 different systems.
No takes yet. Share an insight, caveat, or question.
Billet et al. (1991) studied this question.