Key result
Two-dimensional echocardiography exhibited high consistency (ICC=0.857) and correlation (R=0.75, P<0.01) with cardiovascular MRI for measuring minimal left atrial volume in healthy cats.
Why the study?
This study aimed to assess left atrial size in healthy cats using cardiovascular MRI and compare it with two-dimensional echocardiography.
Does cardiovascular MRI accurately determine left atrial size compared to two-dimensional echocardiography in healthy cats?
Observational (n=6)
Does cardiovascular MRI accurately determine left atrial size compared to two-dimensional echocardiography in healthy cats?
Effect estimate: ICC 0.857, R 0.75
p-value: p=<0.01
Cardiovascular MRI provides reproducible assessment of left atrial mass in cats, while 2D echocardiography remains a reliable tool for measuring minimal LA volume.
Supports the feasibility of advanced imaging for feline left atrial assessment; leaves open whether cardiovascular MRI.
Objectives This study aimed to assess left atrial (LA) size in healthy cats using cardiovascular MRI (cMRI) and to compare this with LA size assessed by two-dimensional echocardiography. The hypothesis was that cMRI would accurately determine LA size in domestic cats. Methods A prospective comparative study was performed. Six healthy cats were selected for the study. Standard two-dimensional echocardiography was performed with and without general anaesthesia. cMRI was conducted under general anaesthesia. A comprehensive analysis of LA mass and function measurements was performed to determine the consistency and correlation of LA size and function indicators between two-dimensional echocardiography and cMRI. Results Our study found that intraobserver variability for cMRI measurements was lower than that for two-dimensional echocardiography. Compared with cMRI, echocardiography under anaesthesia significantly overestimated maximal LA volume (LAVmax_2D, P <0.01) and significantly underestimated minimal LA volume (LAVmin_2D, P <0.01). The LAVmin measured by two-dimensional echocardiography exhibited the highest consistency (intraclass correlation coefficient = 0.857) and correlation ( R = 0.75, P <0.01) with LAVmin measured by cMRI. The linear regression equation was LAVmin_ cMRI = 0.891 × LAVmin_2D + 0.304. Conclusions and relevance cMRI represents a reproducible method for assessing LA mass in domestic cats. This study underscored the importance of echocardiography in veterinary cardiology, and the LAVmin measured by two-dimensional echocardiography may reflect the true LAVmin.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) conducted an observational in Healthy (n=6). Cardiovascular MRI vs. Two-dimensional echocardiography was evaluated on Consistency and correlation of minimal left atrial volume (LAVmin) (ICC 0.857, R 0.75, p=<0.01). Two-dimensional echocardiography exhibited high consistency (ICC=0.857) and correlation (R=0.75, P<0.01) with cardiovascular MRI for measuring minimal left atrial volume in healthy cats.