Why the study?
Does an automatic software tool reduce analysis time while maintaining accuracy compared to a semi-automatic method for global cardiac function assessment using 64-row CT?
Does an automatic software tool reduce analysis time while maintaining accuracy compared to a semi-automatic method for global cardiac function assessment using 64-row CT?
Automatic CT function assessment with manual correction significantly reduces analysis time while providing reliable evaluation of global left ventricular function compared to semi-automatic methods.
May expedite CT LV function workflows in practice; leaves open prospective validation against reference standards before routine adoption.
OBJECTIVE: Global cardiac function assessment using multidetector CT (MDCT) is time-consuming. Therefore we sought to compare an automatic software tool with an established semi-automatic method. METHODS: A total of 36 patients underwent CT with 64 × 0.5 mm detector collimation, and global left ventricular function was subsequently assessed by two independent blinded readers using both an automatic region-growing-based software tool (with and without manual adjustment) and an established semi-automatic software tool. We also analysed automatic motion mapping to identify end-systole. RESULTS: The time needed for assessment using the semi-automatic approach (12:12 ± 6:19 min) was reduced by 75-85% with the automatic software tool (unadjusted, 01:34 ± 0:29 min, adjusted, 02:53 ± 1:19 min; both p<0.001). There was good correlation (r=0.89; p<0.001) for the ejection fraction (EF) between the adjusted automatic (58.6 ± 14.9%) and the semi-automatic (58.0 ± 15.3%) approaches. Also the manually adjusted automatic approach led to significantly smaller limits of agreement than the unadjusted automatic approach for end-diastolic volume (±36.4 ml vs ±58.5 ml, p>0.05). Using motion mapping to automatically identify end-systole reduced analysis time by 95% compared with the semi-automatic approach, but showed inferior precision for EF and end-systolic volume. CONCLUSION: Automatic function assessment using MDCT with manual adjustment shows good agreement with an established semi-automatic approach, while reducing the analysis by 75% to less than 3 min. This suggests that automatic CT function assessment with manual correction may be used for fast, comfortable and reliable evaluation of global left ventricular function.
No takes yet. Share an insight, caveat, or question.
Greupner et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: