Key result
Current utilization patterns for pediatric secundum atrial septal defects resulted in mean charges above optimal standards by $1033 to $5722 depending on lesion severity.
Why the study?
Variation in monitoring secundum atrial septal defects may lead to over-utilisation of routine studies and higher than necessary patient charges.
Does adherence to an optimal utilization standard reduce unnecessary charges in pediatric patients with secundum atrial septal defects?
Observational (n=97)
Does adherence to an optimal utilization standard reduce unnecessary charges in pediatric patients with secundum atrial septal defects?
Answers are grounded in this paper and cite their sources.
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
“This guidance is not meant to replace health care providers' clinical judgment but rather to improve the value of care by reducing practice variation and optimizing resource utilization.”
Adhering to an optimal utilization pathway for monitoring secundum atrial septal defects in infants could significantly reduce unnecessary healthcare charges.
BACKGROUND: There is variation in care of secundum atrial septal defects. Defects <3 mm and patent foramen ovale are not clinically significant. Defects >3 mm are often followed clinically and may require closure. Variation in how these lesions are monitored may result in over-utilisation of routine studies and higher than necessary patient charges. PURPOSE: To determine utilisation patterns for patients with secundum atrial septal defects diagnosed within the first year of life and compare to locally developed optimal utilisation standard to assess charge savings. METHODS: This was a retrospective chart review of patients with secundum atrial septal defects diagnosed within the first year of life. Patients with co-existing cardiac lesions were excluded. Total number of clinic visits, electrocardiograms, and echocardiograms were recorded. Total charge was calculated based on our standard institutional charges. Patients were stratified based on lesion and provider type and then compared to "optimal utilisation" using analysis of variance statistical analysis. RESULTS: Ninety-seven patients were included, 40 had patent foramen ovale (or atrial septal defect <3 mm), 43 had atrial septal defects not requiring intervention and 14 had atrial septal defects requiring intervention. There was a statistically significant difference in mean charge above optimal for these lesions of $1033, $2885, and $5722 (p < 0.02), respectively. There was statistically significant variation of charge among types of provider as well. Average charge savings per patient would be $2530 with total charge savings of $242,472 if the optimal utilisation pathway was followed. CONCLUSION: Using optimal utilisation and decreasing variation could save the patient significant unnecessary charges.
Journal, society, and media accounts. Useful signal, not independent expert judgment.
No takes yet. Share an insight, caveat, or question.
Ziebell et al. (2020) conducted an observational in Secundum atrial septal defects (n=97). Current utilisation patterns vs. Optimal utilisation standard was evaluated on Mean charge above optimal utilisation standard (p=< 0.02). Current utilization patterns for pediatric secundum atrial septal defects resulted in mean charges above optimal standards by $1033 to $5722 depending on lesion severity.
Synapse has enriched 10 related papers. Consider them for comparative context: