Development of a 1 GHz superconducting NMR magnet is in progress at the Tsukuba Magnet Laboratory (TML) of the National Research Institute for Metals (NRIM). This magnet will contain a BSCCO inner coil, which should generate a central field of 23.5 T in a backup field of 21.1 T. In order to accomplish this targeted field, we fabricated two Bi-2212 double-pancake coils (Coil A and Coil B). They were installed in the high-field superconducting magnet system at the TML/NRIM. Their performance was measured in a backup field of 18 T. Coil A was made of 20 double-pancakes wound with Ag sheathed Bi-2212 tape conductors. Ag-Mg tape was co-wound for mechanical support. Its winding was 147 mm in outer diameter and 220 mm in height. It generated a central field of 21.4 T in a clear bore of 61 mm. Coil B was located inside Coil A. Its 6 double-pancakes were wound with Bi-2212 tape conductors reinforced with Ag-Mg-Ni alloy sheath. The outer diameter and height of the winding were 48 mm and 63 mm, respectively. Coil B generated the highest field of 23.4 T in a backup field of 21.4 T. This study confirmed that the present performance of the Bi-2212 coils had already satisfied the required conditions for the inner coil of the 1 GHz NMR magnet from the viewpoint of high-field generation.
No takes yet. Share an insight, caveat, or question.
Kosuge et al. (2000) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: