The influence of compressive and tensile axial strains on the critical current of various Nb/sub 3/Sn conductors is investigated. The investigated multifilamentary wires are especially developed for the ITER project. The critical current is determined as a function of an axial tension in a standard pull set-up. These results are compared with the results that are obtained on a bending spring-type strain device. In this second device an axial compression larger than the integral thermal shrinkage of the matrix, can be achieved. A study of the field dependence of the critical current yields the strain dependence of the extrapolated upper-critical field versus the axial strain. A good correlation is found between the two different strain devices in the tensile strain regime. There is a difference in the (limited) compressive strain regime where such a comparison can be made.