Answers are grounded in this paper and cite their sources.
Few devices used in EMS engender such vehement differences of opinion as the pneumatic anti-shock garment (PASG), otherwise known as the military antishock trouser (MAST).The device achieved widespread civilian use in EMS following its successful field use on casualties suffering from hemorrhagic shock in the Vietnam conflict.Since that time, the PASG has alternately enjoyed tacit acceptance and endured harsh criticism.While the PASG has become one the most widely studied devices used in EMS, interpretation of these studies is intensely debated, with wide divergence of opinions.Initially, the PASG was widely used in the treatment of hemorrhagic shock, where, in the opinion of many, acceptance preceded scientific validation of its clinical efficacy.'-3This tacit acceptance at one time extended to a variety of shock states, including cardiac arrest,4-11 anaphylaxis,12-16 and paroxysmal supraventricular ta~hycardia.'~-'~The PASG has even been successfully used to increase the exercise tolerance of paraplegics.20 Recently, two studies reported increased mortality associated with PASG use in victims of penetrating trauma.21,22Another study refutes this claim in demonstrating increased survival with the PASG in victims of hemorrhagic shock whose initial systolic blood pressures are less than 50 mm Hg.23 Studies of other applications of the PASG, such as in cardiac arrest and spinal shock, failed to reveal any difference in mortality whether or not the device was ~s e d .~-' lThe in-evitable backlash occurred, and the PASG fell into disfavor.Ironically, this widespread condemnation of the PASG took place in the absence of scientific validation that it was detrimental in all situations.Negative outcomes in a limited number of restricted applications have been extrapolated to the broad gamut of clinical situations.Today, the use of the PASG is widely taught to EMS providers,24-26 and the ability to use it is required for NREMT-P certification.27This requirement for certification is in place despite the fact that many systems have sharply restricted PASG use, or have eliminated it altogether.The following discussion summarizes the physiologic effects of the PASG on hemodynamic parameters, pulmonary function, and intracranial pressure.The effects on intravenous fluid therapy, drug delivery, and field treatment time are then discussed.Effects of the environment on inflation pressures, the use of a wide range of inflation pressures, and their impacts on physiologic parameters are explored next.The uses of the PASG in hemorrhagic shock, low cardiac reserve, the elderly, anaphylactic shock, septic shock, hypovolemic (non-hemorrhagic) shock, CPR, abdominal aortic aneurysm (AAA), spinal shock, hypothermia, cardiac tamponade, paroxysmal supraventricular tachycardia (PSVT), pelvic fracture, and local hemorrhage control are summarized.Finally, the safety of using PASG in pregnancy, evisceration, and lower extremity trauma is assessed.
No takes yet. Share an insight, caveat, or question.
O’Connor et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: