This is the authors' abstract. We don't add key points for this paper.
PURPOSE: To introduce a respiratory-gated high-spatiotemporal-resolution dynamic-contrast-enhanced MRI technique and a high-temporal-resolution aortic input function (HTR-AIF) estimation method for glomerular filtration rate (GFR) assessment in children. METHODS: A high-spatiotemporal-resolution DCE-MRI method with view-shared reconstruction was modified to incorporate respiratory gating, and an AIF estimation method that uses a fraction of the k-space data from each respiratory period was developed (HTR-AIF). The method was validated using realistic digital phantom simulations and demonstrated on clinical subjects. The GFR estimates using HTR-AIF were compared with estimates obtained by using an AIF derived directly from the view-shared images. RESULTS: Digital phantom simulations showed that using the HTR-AIF technique gives more accurate AIF estimates (RMSE = 0.0932) compared with the existing estimation method (RMSE = 0.2059) that used view-sharing (VS). For simulated GFR > 27 mL/min, GFR estimation error was between 32% and 17% using view-shared AIF, whereas estimation error was less than 10% using HTR-AIF. In all clinical subjects, the HTR-AIF method resulted in higher GFR estimations than the view-shared method. CONCLUSION: The HTR-AIF method improves the accuracy of both the AIF and GFR estimates derived from the respiratory-gated acquisitions, and makes GFR estimation feasible in free-breathing pediatric subjects.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Yoruk et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: