Key result
Placing the posterosuperior screw 6.5 mm away from the superior border of the femoral neck completely prevented in-out-in screws compared to abutting placement (0% vs 100%).
Why the study?
The posterosuperior screw in cannulated screw fixation for undisplaced femoral neck fractures has a high incidence of cortical breach (in-out-in screw).
Does placing the posterosuperior screw 6.5 mm away from the superior border of the femoral neck prevent in-out-in cortical breach in undisplaced femoral neck fractures?
Does placing the posterosuperior screw 6.5 mm away from the superior border of the femoral neck prevent in-out-in cortical breach in undisplaced femoral neck fractures?
Absolute Event Rate: 0% vs 100%
Placing the posterosuperior screw 6.5 mm away from the superior border of the femoral neck on AP radiographs safely prevents in-out-in cortical breach during fixation of undisplaced femoral neck fractures.
New placement may avoid IOI screws in femoral neck fixation; leaves open prospective clinical validation.
Objective: The inverted triangle configuration of the three cannulated screws is the classic fixation method most commonly performed for undisplaced femoral neck fractures in young and geriatric patients. However, the posterosuperior screw has a high incidence of cortical breach, known as an in-out-in (IOI) screw. In this study, we present a novel posterosuperior screw placement strategy to prevent the screw from becoming IOI. Methods: Using computed tomography data and image-processing software, 91 undisplaced femoral neck fractures were reconstructed. The anteroposterior (AP), lateral, and axial radiographs were simulated. To simulate the intraoperative screw placement process, participants used three screw insertion angles (0°, 10°, and 20°) to place the screw on the AP and lateral views of the radiograph according to the three established strategies. On the AP radiograph, a screw was placed abutting (strategy 1), 3.25 mm away from (strategy 2), or 6.5 mm away from (strategy 3) the superior border of the femoral neck. On the lateral radiograph, all the screws were placed abutting the posterior border of the femoral neck. Axial radiographs were used to evaluate the screw position. Results: In strategy 1, all the placed screws were IOI regardless of the screw insertion angle. In strategy 2, 48.3% (44/91) of IOI screws occurred at a 0° screw insertion angle, 41.7% (38/91) of IOI screws occurred at a 10° screw insertion angle, and 42.9% (39/91) of IOI screws occurred at a 20° screw insertion angle situation. In strategy 3, no IOI screw occurred, and the screw insertion angles did not affect the safety and accuracy of screw placement. Conclusions: Screws placed according to strategy 3 are safe. The reliability of this screw placement strategy is unaffected by a screw insertion angle of less than 20 degrees.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) studied undisplaced femoral neck fractures (n=91). Posterosuperior screw placement 6.5 mm away from the superior border of the femoral neck (Strategy 3) vs. Screw placed abutting (Strategy 1) or 3.25 mm away from (Strategy 2) the superior border was evaluated on Incidence of in-out-in (IOI) screws. Placing the posterosuperior screw 6.5 mm away from the superior border of the femoral neck completely prevented in-out-in screws compared to abutting placement (0% vs 100%).
Synapse has enriched 5 related papers. Consider them for comparative context: