Key result
The presence of a peripheral tubular component on helical CT arteriography identified type II endoleaks with 100% sensitivity and 88.2% specificity (P < .001).
Why the study?
Does the presence of a peripheral tubular component on helical CT arteriography accurately diagnose type II endoleaks in patients after endoaortic graft implantation?
Observational (n=39)
Does the presence of a peripheral tubular component on helical CT arteriography accurately diagnose type II endoleaks in patients after endoaortic graft implantation?
The presence of a peripheral tubular component on helical CT arteriography is a highly sensitive and accurate predictor of type II endoleaks after endoaortic graft implantation.
Answers are grounded in this paper and cite their sources.
May aid noninvasive detection of type II endoleaks after EVAR; leaves open need for prospective validation before practice change.
PURPOSE: To retrospectively assess endoleak shapes and locations within aneurysms to differentiate type II from type I and type III endoleaks. MATERIALS AND METHODS: The institutional review board granted an exemption for this HIPAA-compliant study; patient informed consent was not required. A retrospective review of arterial phase helical computed tomographic (CT) studies and medical records was performed for 39 patients (29 men, 10 women; age range, 60-89 years; mean, 78.5 years) who had an endoleak after endoaortic graft implantation for treatment of abdominal aortic aneurysm and who subsequently underwent angiography (n = 25), surgery (n = 8), or long-term follow-up (n = 6) to classify their endoleak into a specific type. At CT, endoleak shape (tubular or nontubular) and location (central or peripheral) were recorded. An endoleak was classified as type II if it contained a peripheral tubular component (PTC) near the aortic wall, with or without an identifiable feeding vessel. Endoleaks without these features were classified as type I or III. The Fisher exact test was used to assess associations between CT findings and endoleak type. RESULTS: There were 22 type II and 17 type I or III endoleaks. CT enabled correct identification of 22 (100%) of 22 type II endoleaks, all of which contained a PTC. Of 17 type I or III endoleaks, only two (12%) contained a PTC and were misclassified as type II endoleaks; the remaining 15 (88%) were correctly classified. Overall, CT enabled correct identification of endoleaks as type II or type I or III in 37 (95%) of 39 patients. PTCs were significantly more common (P < .001) in type II than in type I or III endoleaks, with a sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of 100%, 88.2%, 94.9%, 100%, and 91.7%, respectively. CONCLUSION: A PTC is a statistically significant predictor of type II endoleak in most patients.
No takes yet. Share an insight, caveat, or question.
Chernyak et al. (2006) conducted an observational in Endoleak after endoaortic graft implantation for abdominal aortic aneurysm (n=39). Peripheral tubular component (PTC) on helical CT arteriography vs. Absence of PTC was evaluated on Identification of type II endoleak (p=< .001). The presence of a peripheral tubular component on helical CT arteriography identified type II endoleaks with 100% sensitivity and 88.2% specificity (P < .001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: