Answers are grounded in this paper and cite their sources.
In this work, a reactive argon−nitrogen [ Ar/N 2 ( 10 / 1 ) ] dc magnetron plasma for sputtering of a chromium (Cr) target is characterized with high spatial resolution by optical emission spectroscopy (OES) using molecular nitrogen emission bands at 0.5 Pa and 100 W. Beside the global gas temperature T g , the electron temperature T e , electron density n e , and the steady-state Cr density n Cr are also determined spatially resolved using a movable OES setup inside the chamber and Abel inversion. n e and T e are found to be consistent with the values measured by a Langmuir probe (LP) within the non-magnetized region along the magnetron axis in a pure Ar plasma for the same process parameters. Finally, a nitrogen content c N of 4% in the target surface is found for the reactive plasma by matching the mean steady-state chromium density n ¯ Cr measured by OES and calculated from TRIDYN simulations.
No takes yet. Share an insight, caveat, or question.
Ries et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: