Why the study?
Does rapid preload reduction via inferior vena caval occlusion induce pulsus alternans and alter left ventricular performance in patients with nonischemic cardiomyopathy?
Does rapid preload reduction via inferior vena caval occlusion induce pulsus alternans and alter left ventricular performance in patients with nonischemic cardiomyopathy?
Rapid preload reduction via IVC occlusion can induce pulsus alternans in nonischemic cardiomyopathy, driven by beat-to-beat alternations in preload and intrinsic contractile forces.
Answers are grounded in this paper and cite their sources.
Preload reduction may induce pulsus alternans in nonischemic cardiomyopathy; hypothesis-generating and should not yet change practice.
To assess the effect of rapid preload reduction on left ventricular performance in nonischemic cardiomyopathy, 11 patients were studied during inferior vena caval (IVC) balloon occlusion. Five developed sustained pulsus alternans. During pulsus alternans, the strong beats demonstrated systolic performance characteristics similar to baseline values, despite a drop in both left ventricular (LV) end-diastolic diameter (66 +/- 13 to 61 +/- 13 mm; p less than 0.05) and LV end-diastolic pressure (21 +/- 8 to 9 +/- 6 mmHg; p less than 0.05). In contrast, the weak beats demonstrated a reduction in peak systolic pressure (130 +/- 36 to 109 +/- 33 mmHg; p less than 0.02), fractional shortening (20% +/- 4% to 17% +/- 9%; p less than 0.05) and peak positive dP/dt (1,006 +/- 224 to 921 +/- 287 mmHg; p less than 0.05). Measures of diastolic performance (peak negative dP/dt, the time constant of LV relaxation, the length of diastasis, and LV end-diastolic stress) were not different between baseline beats and the strong beats; and only LV end-diastolic stress differed when baseline beats were compared to the weak beats. When the strong beats were compared to the weak beats during induced pulsus alternans, significant differences were observed in peak systolic pressure, peak positive dP/dt, and fractional shortening, but no differences in any measured diastolic parameter was observed. A slight difference was noted in the left ventricular end-diastolic diameters, with the weak beat consistently beginning at a slightly smaller diameter (61 +/- 13; mm vs 59 +/- 13; p less than 0.05). In summary, these data are consistent with an augmentation and deletion of intrinsic contractile forces in association with an alternation in preload on a beat-to-beat basis as best describing left ventricular performance during pulsus alternans.
No takes yet. Share an insight, caveat, or question.
Bashore et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: