Key result
Strong beats in pulsus alternans show ~5 percentage points greater LV minor axis shortening vs. weak beats.
Why the study?
This study evaluated the influence of pulsus alternans on systolic and diastolic function in patients with severe aortic valve disease.
Does pulsus alternans influence left ventricular systolic and diastolic function between strong and weak beats in patients with severe aortic valve disease?
Observational (n=12)
Does pulsus alternans influence left ventricular systolic and diastolic function between strong and weak beats in patients with severe aortic valve disease?
In patients with severe aortic valve disease and pulsus alternans, strong beats exhibit significantly higher peak systolic pressure, end-systolic pressure, max dP/dt, and left ventricular minor axis shortening compared to weak beats, despite unchanged end-diastolic pressure and peak contractile element shortening velocity.
Answers are grounded in this paper and cite their sources.
May signal altered function in aortic valve disease; leaves open clinical utility pending prospective validation.
Left ventricular high fidelity pressure measurements and simultaneous biplane cineangiocardiography were performed in 12 patients with severe aortic valve disease (aortic stenosis in 10, aortic insufficiency in 1 and combined valve lesion in 1). Left ventricular contractility was estimated from maximal rate of left ventricular pressure rise (max dP/dt), peak measured velocity of contractile element shortening (Vpm) and mean circumferential fiber shortening velocity. Left ventricular relaxation was assessed in 12 patients from the time constant (T) of the decline in left ventricular pressure; this constant was calculated from a nonlinear regression analysis of pressure and time (method 1) and a linear regression analysis of pressure and negative dP/dt (method 2). Left ventricular diastolic function was evaluated in nine patients from simultaneous diastolic pressure-volume relations during the strong and weak beats. During pulsus alternans, heart rate and left ventricular end-diastolic pressure remained unchanged, whereas peak systolic pressure (220 versus 204 mm Hg, p less than 0.01) and end-systolic pressure (101 versus 95 mm Hg, p less than 0.01) were significantly higher during the strong beat than during the weak beat. Max dP/dt was alternating (2,162 versus 1,964 mm Hg, p less than 0.05), whereas the peak velocity of contractile element shortening remained unchanged (1.21 versus 1.18 ML/s). Systolic shortening of the left ventricular minor axis was significantly (p less than 0.02) greater during the strong (24%) than during the weak (19%) beat, but that of the left ventricular major axis remained essentially unchanged (8 versus 7%).(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Hess et al. (1984) conducted an observational in Severe aortic valve disease with pulsus alternans (n=12). Pulsus alternans (strong beat) vs. Pulsus alternans (weak beat) was evaluated on Left ventricular systolic shortening of the minor axis (p=<0.02). Pulsus alternans strong beats exhibited higher peak systolic pressure and LV minor axis shortening than weak beats.
Synapse has enriched 10 related papers. Consider them for comparative context: