Key result
Pulmonary capillary wedge pressure overestimates prosthetic mitral valve gradients vs transseptal catheterization in 100% of cases.
Why the study?
In patients with symptoms of heart failure after mitral valve replacement, identification of a stenosed prosthesis may be difficult.
Does direct transseptal catheterization provide more accurate prosthetic mitral valve area and diastolic gradient determinations compared to indirect pulmonary capillary wedge pressure in patients with heart failure symptoms after mitral valve replacement?
Observational (n=12)
Does direct transseptal catheterization provide more accurate prosthetic mitral valve area and diastolic gradient determinations compared to indirect pulmonary capillary wedge pressure in patients with heart failure symptoms after mitral valve replacement?
Direct transseptal catheterization prevents overestimation of transvalvular gradients and underestimation of prosthetic mitral valve area caused by relying on pulmonary capillary wedge pressure, potentially avoiding unnecessary repeat mitral valve surgery.
Answers are grounded in this paper and cite their sources.
Transseptal catheterization may avert unnecessary mitral reoperations by correcting area underestimation; leaves open need for prospective validation before adoption.
In patients with symptoms of heart failure after mitral valve replacement, identification of a stenosed prosthesis may be difficult. Twelve such patients were evaluated, presenting at a mean of 8.4 years after mitral valve replacement (four mechanical, eight porcine). Transvalvular pressure gradients were obtained using both indirect (pulmonary capillary wedge) and direct (transseptal catheterization) measurements of left atrial pressure. In all 12 patients, the diastolic gradient across the prosthetic valve was overestimated when pulmonary wedge rather than transseptal measurements were used. Calculated mitral valve prosthetic area was underestimated by the pulmonary wedge determinations. These findings may be caused by either the phase delay of the pulmonary wedge V wave relative to the transseptal V wave, resulting in a higher diastolic mean left atrial pressure, or the faulty wedge determinations in the setting of pulmonary hypertension, or both. In patients being considered for repeat mitral valve replacement because of prosthetic valve stenosis, transseptal catheterization allows for more accurate determination of prosthetic valve area and more accurately defines the need for repeat mitral valve surgery.
No takes yet. Share an insight, caveat, or question.
Schoenfeld et al. (1985) conducted an observational in Prosthetic mitral valve stenosis with heart failure symptoms (n=12). Pulmonary capillary wedge pressure measurement vs. Transseptal catheterization was evaluated on Overestimation of diastolic gradient and underestimation of prosthetic mitral valve area. Pulmonary capillary wedge measurements overestimated the prosthetic mitral valve diastolic gradient and underestimated valve area compared to transseptal catheterization in 100% (12/12) of patients.