Direct measurement of aortic flow velocity confirms that stroke volume varies beat-to-beat in patients with pulsus alternans.
Answers are grounded in this paper and cite their sources.
Confirms stroke volume variation in pulsus alternans via direct flow; leaves open whether velocity monitoring informs management beyond this case.
Phasic aortic flow velocity was recorded in two patients with pulsus alternans using a flow velocity probe connected to a Doppler ultrasonic flowmeter system. The variations in beat-to-beat peak velocity paralleled the variations in arterial and ventricular systolic pressures. This study provides direct evidence that stroke volume varies during this abnormal haemodynamic status. It is conceivable, though not proved in this study, that this phenomenon may be secondary to alternation between large and small end-diastolic fibre length.
No takes yet. Share an insight, caveat, or question.
Benchimol et al. (1970) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: