Aortic valve repair for rheumatic aortic regurgitation is feasible and yields good results in a majority of patients, though it is associated with a notable rate of early and late failures requiring replacement.
Answers are grounded in this paper and cite their sources.
Should not yet change practice in rheumatic AR; leaves open durability and selection criteria for prospective validation.
Twenty-two patients underwent aortic valve repair for rheumatic aortic regurgitation (AR) from April 1991 to August 1993. Six patients were female. Thirteen patients required mitral valve repair and 3 patients underwent mitral valve replacement. One patient required tricuspid valve repair in addition to aortic and mitral valve reconstruction. There was 1 early death and 5 early failures. Of these, 3 were considered unsatisfactory valves for repair and replaced after an attempt at repair. In 2 others, the aortic valve was replaced within a week of initial attempt at repair. There were 2 late failures, 1 of which had aortic valve replacement and another who is awaiting reoperation. Fourteen of 22 patients have been judged to have good results clinically and echocardiographically.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: