Why the study?
Bleeding during coronary artery bypass surgery is a leading cause of mortality, with platelet dysfunction being the most significant associated factor.
Does cardiopulmonary bypass affect platelet function and correlate with intra-operative hemoglobin drop in adult patients undergoing cardiac surgery?
Does cardiopulmonary bypass affect platelet function and correlate with intra-operative hemoglobin drop in adult patients undergoing cardiac surgery?
PFA-100 is sensitive and positively predicts intra-operative hemoglobin drop during cardiopulmonary bypass, suggesting its utility in identifying high-risk cardiac surgery patients for bleeding.
Answers are grounded in this paper and cite their sources.
CPB-related platelet dysfunction may heighten bleeding risk; leaves open utility of PFA-100/MEA monitoring in cardiac surgery.
Background: Bleeding during coronary artery bypass surgery is a leading cause of mortality. Several factors have been associated with bleeding, platelet dysfunction being the most significant.Objective: to assess the effect of cardiopulmonary bypass machine (CPB) during cardiac surgery on platelet function using Platelet Function Analyzers (PFA-100), and Multiplate Electrode Aggregometry (MEA), and correlating that with a drop in Hemoglobin (Hb).Methods: Whole blood samples were collected preoperative and sixty minutes intraoperatively of different cardiac procedures utilizing (CPB) and tested for platelet function by PFA-100 and MEA. Complete blood count was measured using an automated hematology analyzer.Results: A significant difference was found between pre- and intraoperative ADP and EPI measurement in PFA-100, where preoperative PFA-ADP values displayed the ability to predict the intra-op drop in Hb (P–value 0.01, correlation coefficient 0.4699). At the same time, pre-op MEA- Ristocetin and TRAP showed an inverse correlation with an intra-op drop in Hb (-0.31 and -0.36). Conclusion: The current study reported significant changes in platelet dysfunction in cardiac surgeries with CPB, measured by two modalities PFA-100, and MEA. While PFA-100 and MEA both detected the changes in platelet dysfunction due to CPB, PFA-100 results were sensitive and positively predicted intra-op Hb drop as compared to MEA. There was a significant change in Hb one hour into the CPB, indicating that platelet transfusion might help decrease Intra- and postoperative bleeding independent of the platelet count as they are dysfunctional. PFA-100 results can be relied upon for distinction of high-risk cardiac surgery patients for bleeding and can be used for clinical decision making to improve patient outcome.
No takes yet. Share an insight, caveat, or question.
Alsaleh et al. (2020) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: