Answers are grounded in this paper and cite their sources.
A new charge-pump circuit with the controllable body voltage is proposed. By adjusting the body voltage, the back bias effect is removed and the threshold voltage of the MOSFET used as a switch is kept constant. With no threshold voltage increase, higher output voltage than the conventional charge pump can be obtained in the proposed charge pump. With two auxiliary MOSFETs used to update the body voltage, the proposed charge pump shows compatible performance of the ideal diode charge pump.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: