Why the study?
Polymeric leaflet-structures represent a promising alternative to xenogenic materials for transcatheter heart valve prostheses, but limitations regarding calcification and durability require in silico assessment via a constitutive material law.
Answers are grounded in this paper and cite their sources.
Finite-element analysis using a validated hyperelastic constitutive law is a useful tool for evaluating the in silico performance of polymeric leaflet-structures for transcatheter heart valves.
While the current generation of devices for minimally invasive treatment of severe symptomatic aortic valve stenosis is based on xenogenic leaflet-material, artificial polymeric leaflet-structures represent a promising approach for future improvement of heart valve performance. For enhanced long-term success of polymeric leafletstructures, limitations regarding calcification and durability have to be addressed. The objective of the presented study was the development of a constitutive law representing the material properties of artificial polymeric leaflet-structures of transcatheter heart valve prostheses in numerical simulation to assess the in silico leaflet-performance. Mechanical characterization of cast films and nonwoven specimens of a polycarbonate based silicone elastomer were conducted by means of uniaxial tension and planar shear testing, respectively. For validation purposes, experimental data were compared with the results of finite-element analysis (FEA) using different hyperelastic models. Strain energy function for third-order ogden hyperelastic model achieved the best fit of the non-linear stress-strain behavior of the isotropic polymeric material with the experimental data. It was chosen for further FEA of valve leaflet-performance under physiological pressurization to analyze the suitability of various manufacturing processes for polymeric leafletstructures. Therefore a specific leaflet-design with a wall thickness of 400 μm was used. As a result of FEA, time dependent leaflet-deformation, leaflet coaptation surface area (CSA) and leaflet opening area (LOA) of cast and nonwoven leaflet-structures were calculated. While LOA was comparable for cast and nonwoven leaflet-structures, obtained leaflet-dynamics in a cardiac cycle under physiological pressurization demonstrated crucial influence of the manufacturing process. For nonwoven leafletstructures, an enhanced CSA could be demonstrated in comparison to cast structures. FEA using a validated hyperelastic constitutive law represents a useful tool for in silico performance evaluation of polymeric leaflet-structures under physiological loading and proves the suitability of the polymeric artificial leaflet-material for percutaneous heart valve prostheses.
No takes yet. Share an insight, caveat, or question.
Pfensig et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: