Key points are not available for this paper at this time.
Design
Analytical laboratory method development and validation study
Answers are grounded in this paper and cite their sources.
A rapid and precise HPLC method was successfully developed and validated for the simultaneous quantification of amlodipine besylate and enalapril maleate in solid dosage forms.
A rapid, sensitive, specific, accurate and precise high pressure liquid chromatographic method (HPLC) method involving UV detection has been developed for the determination and quantification of Amlodipine Besylate and Enalapril maleate in bulk and combined dosage form. The determination was carried out on a Phenomenex C18 column (Dimention : 250 x 4.6 mm, 5 μm). The sample was analysed using filtered and degassed mixture of methanol : 0.1N HCl (1:1) as mobile phase at a flow rate of 1ml/min and effluent was monitored at 218nm. The retention time for Amlodipine besylate was 7.6 min and for Enalapril maleate 3.2 min. Amlodipine besylate and Enalapril maleate showed a linear response in the concentration range of 10-50μg/ml. The correlation co-efficient ('r' value) for Amlodipine besylate and Enalapril maleate was 0.9992 and 0.9994, respectively. The method was validated in terms of linearity, precision, accuracy, specificity, robustness and solution stability. The proposed method can be used for routine analysis of Amlodipine Besylate and Enalapril maleate in bulk and combined dosage form
No takes yet. Share an insight, caveat, or question.
Manisha Masih (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: