Why the study?
Unplanned downtime due to circuit coagulation in regional citrate anticoagulation-continuous renal replacement therapy is as high as 15.75%-66.70%.
Can a nomogram model accurately predict the lifespan of RCA-CRRT circuits in intensive care patients with acute kidney injury?
Can a nomogram model accurately predict the lifespan of RCA-CRRT circuits in intensive care patients with acute kidney injury?
A newly developed nomogram incorporating clinical and laboratory parameters can accurately predict the lifespan of RCA-CRRT circuits, potentially reducing unplanned downtime.
Nomogram may aid RCA-CRRT circuit planning in ICU; hypothesis-generating pending multicenter validation.
BACKGROUND: Regional citrate anticoagulation-continuous renal replacement therapy (RCA-CRRT) has a wide range of applications in clinical practice, but unplanned downtime due to RCA-CRRT circuit coagulation is as high as 15.75%-66.70%. AIM: To build a nomogram model for predicting the lifespan circuits of RCA-CRRT. STUDY DESIGN: A prospective observational cohort study was conducted in Sichuan, China. The collected clinical data from 404 RCA-CRRT sessions involving 135 patients were utilized. The patients' basic information, laboratory indicators and RCA-CRRT parameters were used as independent variables, and the survival status and survival time of RCA-CRRT circuits were used as dependent variables. A Cox multivariate analysis was performed to build the nomogram model for predicting the lifespan of RCA-CRRT circuits. The model was validated internally and externally. RESULTS: The median lifespan of RCA-CRRT circuits was 28.0 (12.0-46.5) h, and the unplanned downtime rate was 23.76%. In the Cox multivariate analysis, venous pressure, haemoglobin, Sequential Organ Failure Assessment (SOFA), lactate, and blood transfusion were identified as statistically significant predictive factors for the lifespan of RCA-CRRT circuits (p < .05). Subsequently, a nomogram model for predicting the lifespan of RCA-CRRT circuits was developed. The AUC values for internal and external validation within the 12-72-h timeframe ranged from 0.648 to 0.816 and 0.613 to 0.956, respectively. Both the calibration curve and clinical decision curve demonstrated the model's good performance. CONCLUSION: The nomogram model developed in this study demonstrates its efficacy in accurately predicting the lifespan circuits of RCA-CRRT. RELEVANCE TO CLINICAL PRACTICE: Clinical nurses can use the prediction model to assess the lifespan of RCA-CRRT circuits, so as to formulate a personalized RCA-CRRT treatment plan for patients, thus reducing the unplanned downtime of RCA-CRRT.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: