Why the study?
What are the predictors of reperfusion times and the reliability of nurse-recorded times in patients undergoing primary PCI for ST-elevation ACS?
What are the predictors of reperfusion times and the reliability of nurse-recorded times in patients undergoing primary PCI for ST-elevation ACS?
Nurse-recorded reperfusion times in primary PCI may be unreliable compared to digital recordings, and older age and elevated creatinine are associated with longer reperfusion times.
Answers are grounded in this paper and cite their sources.
Nurse-recorded D2B times may overestimate intervals versus PCI logs; leaves open validation of automated systems for quality metrics in primary PCI.
BACKGROUND: There is wide variation in recording of reperfusion times in the management of ST segment elevation acute coronary syndromes (ACS). We investigated factors that could predict time to reperfusion. METHODS: Single-centre, retrospective study of all consecutive patients admitted for primary PCI from June 2009 to October 2010. Door-to-artery (D2A) and Door-to-balloon (D2B) times were calculated from times noted by cathlab. nurses and compared with times from digital recordings of PCI procedures. Predictors of time to reperfusion were identified by logistic regression. RESULTS: 300 patients were included. Median (interquartile range) D2B time recorded by cathlab. nurses (D2B-CN) was 35.5 (24; 52) minutes, 32 (20; 51) min from PCI recordings (D2B-PCI). Average difference between D2B-CN and D2B-PCI was 6.2 min (P < 0.0001). Concordance of percent patients with a D2B time < 90 and < 45 min was mediocre, kappa coefficients 0.44 (95% CI: 0.10-0.79) and 0.68 (95% CI: 0.57-0.80) respectively. By multivariate analysis, older patients had longest D2A times (P = 0.04); patients with longest D2A and D2B times more frequently had elevated creatinine (P = 0.002 (D2A), P = 0.0003 (D2B). Organizational aspects did not influence reperfusion times. CONCLUSION: Data regarding reperfusion times are unreliable when recorded by nurses. Age and creatinine levels are significantly associated with reperfusion times, whereas organizational aspects are not.
No takes yet. Share an insight, caveat, or question.
Plastaras et al. (2011) studied this question.