Why the study?
The clinical significance of the maximal first derivative of the radial pulse wave in monitoring cardiac function in perioperative patients was not well established.
Does the maximal first derivative of the radial pulse wave (Rad dP/dtmax) correlate with cardiac output in perioperative patients?
Does the maximal first derivative of the radial pulse wave (Rad dP/dtmax) correlate with cardiac output in perioperative patients?
Rad dP/dtmax may serve as a useful indicator for monitoring acute changes in cardiac function in perioperative patients, particularly those with cardiac dysfunction.
May support Rad dP/dtmax as CO surrogate in small CABG cohort; leaves open validation before clinical adoption.
BACKGROUND: This study aimed to assess the clinical significance of the maximal first derivative of the radial pulse wave (Rad dP/dtmax) in monitoring cardiac function with different perioperative patients by researching the relationship between Rad dP/dtmax and cardiac output (CO). METHODS: Patients with non-pump coronary artery bypass grafting (CABG) and open liver tumor resection (OLTR) were enrolled in this study (n=10). CO was measured using the thermodilution Swan-Ganz catheter method and Rad dP/dtmax was acquired by the analysis of patients' left radial artery pressure waveform through the PowerLab data acquisition device. CO, Rad dP/dtmax, heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure, central venous pressure, mean pulmonary arterial pressure, pulmonary artery wedge pressure (PAW), and body surface area was recorded. Data were analyzed using a mixed linear model of time-dependent covariates to duplicate the data. RESULTS: The bivariate correlation coefficients of Rad dP/dtmax and CO were 0.526 and 0.413. The result of the multivariate mixed linear model analysis showed that compared with other indicators, Rad dP/dtmax had the greatest standardized coefficient with CO in CABG patients. While in OLTR patients, HR, SBP, PAW, and DBP had larger standardized coefficients. CONCLUSIONS: Rad dP/dtmax could be a useful indicator to reflect and predict the acute changes in cardiac function in perioperative patients, especially for patients with cardiac dysfunction or contractility abnormality.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2020) studied this question.