Why the study?
Does baseline left ventricular dP/dt(max) predict 1-year clinical outcome in patients receiving cardiac resynchronization therapy?
Does baseline left ventricular dP/dt(max) predict 1-year clinical outcome in patients receiving cardiac resynchronization therapy?
Baseline left ventricular dP/dt(max), rather than its acute improvement, predicts 1-year survival free from mortality, heart transplantation, or LVAD implantation in patients receiving cardiac resynchronization therapy.
Answers are grounded in this paper and cite their sources.
Baseline LV dP/dt(max) was associated with CRT outcome; hypothesis-generating for risk stratification and requires prospective validation.
AIMS: The maximum rate of left ventricular (LV) pressure rise (dP/dt(max)) has been used to assess the acute haemodynamic effect of cardiac resynchronization therapy (CRT). We tested the hypothesis that LV dP/dt(max) predicts long-term clinical outcome after initiation of CRT. METHODS AND RESULTS: This was a retrospective observational multicentre study in 285 patients in whom dP/dt(max) was measured invasively following implantation of a CRT device. The minimum required follow-up was 1 year. We analysed the relationship between dP/dt(max) and time to the composite endpoint, consisting of all-cause mortality, heart transplantation (HTX), or LV assist device (LVAD) implantation within the first year of CRT. Thirty-four events occurred after a mean follow-up of 160 days (range 21-359). Patients with an event had lower dP/dt(max) than patients without an event both at baseline (705 ± 194 vs. 800 ± 222 mmHg/s, P= 0.018) and during CRT (894 ± 224 vs. 985 ± 244 mmHg/s, P= 0.033), but the acute increase in dP/dt(max) was similar in patients with and without an event (190 ± 133 vs. 185 ± 115 mmHg/s, P= n.s.). Left ventricular dP/dt(max)-level at baseline and during CRT both predicted the clinical outcome after adjustment for gender, aetiology and New York Heart Association class: hazard ratio (HR) 0.791 [95% confidence interval (CI) 0.658-0.950, P= 0.012] and HR 0.846 (95% CI 0.723-0.991, P= 0.038), respectively. CONCLUSION: Left ventricular dP/dt(max) measured at baseline and during CRT are predictors of 1-year survival free from all-cause mortality, HTX, or LVAD implantation, but the acute improvement in dP/dt(max) is not correlated to clinical outcome.
No takes yet. Share an insight, caveat, or question.
Bogaard et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: