Why the study?
Does P-wave triggered SAECG predict the induction of atrial fibrillation or flutter by transesophageal pacing in patients with palpitations?
Does P-wave triggered SAECG predict the induction of atrial fibrillation or flutter by transesophageal pacing in patients with palpitations?
P-wave triggered SAECG, particularly prolonged P-wave duration, serves as a useful noninvasive tool to identify patients with palpitations at risk for electrically-inducible atrial fibrillation or flutter.
Answers are grounded in this paper and cite their sources.
Prolonged P-wave duration on triggered SAECG was associated with inducible AF/flutter; hypothesis-generating for noninvasive prediction, needs prospective validation.
Background: Transesophageal pacing (TEP) may be a useful tool in the evaluation of patients with palpitations. The induction of atrial tachyarrythmia by TEP often allows the detection of an underlying re‐entrant atrial arrhythmia as a cause of the patients' symptoms. Recently, the P‐wave triggered signal‐averaged electrocardiogram (SAECG) has been used to detect patients at risk of paroxysmal atrial tachyarrhythmias. The aim of this study was to investigate the usefulness of the P‐wave triggered SAECG applied in a group of patients with a history of paroxysmal palpitations to identify those prone to the development of electrically‐induced atrial flutter or fibrillation. Methods: The study population consisted of 46 patients (31 men, mean age 43 ± 11 years) investigated for palpitations with concomitant symptoms of dizziness or presyncope. Patients were divided into 2 groups according to the presence or absence of an atrial arrhythmia induced by TEP. Twenty‐six consecutive patients (18 men, mean age 44 ± 13 years) demonstrated electrically‐inducible, sustained (lasting < 30 s) atrial fibrillation or atrial flutter (arrhythmia group). The control group comprised 20 patients (13 men, mean age 44 ± 9 years) with similar symptoms, but without significant atrial arrhythmia induced by TEP. The following P‐wave triggered SAECG indices were calculated: the root mean square voltage for the terminal 10, 20, 30 ms of the filtered P‐wave (RMS10,20,30) and time duration of the filtered P‐wave (PWD). Results: Patients with atrial fibrillation or flutter induced by TEP demonstrated significantly longer values of the PWD compared to controls (126.5 ± 15.9 ms vs. 108.0 ± 7.0 ms respectively, P > 0.0001). In the former group we also found the decreased voltage of the terminal part of the P‐wave: RMS10 (4.1 ± 1.1 ptV vs 5.5 ± 2.1 pV, P = 0.002), RMS20 (5.1 ± 1.4 μ V vs. 7.3 ± 2.6 μ V, P = 0.0007), and RMS30 (6.2 ± 1.8 μ V vs. 8.7 ± 2.5 μ V, P = 0.0003) (all comparisons arrhythmia group vs controls, respectively). Moreover, a value of PWD < 117 ms appeared to have practical value in the detection patients at risk of atrial fibrillation or flutter induced by TEP, with a specificity of 90%, sensitivity of 77%, and positive predictive value of 91%. Conclusion: We conclude that among patients presenting with paroxysmal palpitations the P‐wave triggered SAECG had practical value as an noninvasive method to identify those at risk of electrically‐inducible atrial fibrillation and flutter. To what extent this could improve the management of these patients merits further evaluation. A.N.E. 1999;4(1):46–52
No takes yet. Share an insight, caveat, or question.
Banasiak et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: