Key result
Frequency-domain analysis of P waves provided an 83% predictive accuracy for detecting paroxysmal atrial fibrillation, with significant differences compared to controls.
Why the study?
Does frequency- and time-domain analysis of P-SAECG accurately detect patients with paroxysmal atrial fibrillation?
Case-Control (n=42)
Does frequency- and time-domain analysis of P-SAECG accurately detect patients with paroxysmal atrial fibrillation?
Frequency-domain analysis of P waves in lateral leads provides accurate predictability for detecting patients with paroxysmal atrial fibrillation.
Answers are grounded in this paper and cite their sources.
May support P-wave analysis for paroxysmal AF detection; leaves open prospective validation before clinical adoption.
We investigated the usefulness of the time- and frequency-domain analysis of the P wave triggered signal-averaged ECG (P-SAECG) for detecting patients with paroxysmal atrial fibrillation (Paf). In previous studies, the usefulness of the time domain of the P-SAECG to detect patients with Paf was described but that of the frequency domain is unknown. We analyzed the P-SAECG in the time and frequency domain in 23 patients with Paf and 19 controls. The 32-unipolar chest lead ECGs and the standard bipolar limb lead ECGs were obtained. The time-domain analysis showed that the filtered P duration (fPd) was significantly longer (P < 0.01) in patients with Paf than controls: the predictive accuracy of Paf with fPd > 120 ms was 69%. The frequency domain analysis showed that the area ratio of power spectrum area of 0-20 Hz to 20-100 Hz (AR20) was significantly higher (P < 0.01) and the magnitude ratio at 30 Hz (%Mag.30) calculated by dividing the magnitude at 30 Hz by the maximal magnitude was significantly (P < 0.01) lower in patients with Paf than controls in the left lateral chest leads. The predictive accuracy of Paf with AR20 > or = 1.5 and that with %Mag.30 < 40% was 83% and 73%, respectively. Our results indicate that the frequency-domain analysis of P waves in lateral leads is useful as is the time-domain analysis to detect patients with Paf. The AR20 > or = 1.5 and %Mag.30 < 40% provides accurate predictability of Paf.
No takes yet. Share an insight, caveat, or question.
Hiraki et al. (1998) conducted a case-control in Paroxysmal atrial fibrillation (n=42). Frequency- and time-domain analysis of P-SAECG vs. Controls was evaluated on Predictive accuracy for paroxysmal atrial fibrillation (p=<0.01). Frequency-domain analysis of P waves provided an 83% predictive accuracy for detecting paroxysmal atrial fibrillation, with significant differences compared to controls.