Why the study?
Stroke remains a major complication in heart failure patients on LVAD support, but quantitative assessment of hemodynamic variables and their relation to stroke outcomes remains challenging.
Do in silico hemodynamic descriptors differ between LVAD patients with and without stroke outcomes?
Do in silico hemodynamic descriptors differ between LVAD patients with and without stroke outcomes?
In silico quantitative analysis of hemodynamics after LVAD implantation reveals alterations that may be linked to stroke outcomes, potentially aiding in surgical optimization and risk assessment.
Pre-implantation hemodynamic assessment may aid post-LVAD stroke risk stratification; leaves open prospective validation before practice change.
Stroke remains a leading cause of complications and mortality in heart failure patients treated with a Left Ventricular Assist Device (LVAD). Hemodynamics plays a central role underlying post-LVAD stroke risk and etiology. Yet, detailed quantitative assessment of hemodynamic variables and their relation to stroke outcomes in patients on LVAD support remains a challenge. Modalities for pre-implantation assessment of post-implantation hemodynamics can help address this challenge. We present an in silico hemodynamics analysis for a digital twin cohort 12 patients on LVAD support; 6 with reported stroke outcomes and 6 without. For each patient we created a post-implant twin with the LVAD outflow graft reconstructed from cardiac-gated CT images; and a pre-implant twin of an estimated baseline flow by removing the LVAD outflow graft and driving flow from the aortic valve opening. Hemodynamics was characterized using descriptors for helical flow, vortex generation, and wall shear stress. We observed higher average values for descriptors of positive helical flow, vortex generation, and wall shear stress, across the 6 cases with stroke outcomes when compared with cases without stroke. When the descriptors for LVAD-driven flow were compared against estimated pre-implantation flow, extent of positive helicity was higher, and vorticity and wall shear were lower in cases with stroke compared to those without. Our study suggests that quantitative analysis of hemodynamics after LVAD implantation; and hemodynamic alterations from a pre-implant flow scenario, can potentially reveal hidden information linked to stroke outcomes during LVAD support. This has broad implications on understanding stroke etiology; and using patient digital twins for LVAD treatment planning, surgical optimization, and efficacy assessment.
No takes yet. Share an insight, caveat, or question.
Sahni et al. (2023) studied this question.