Key result
Routine 3D echocardiography was technically feasible in 83% of patients and changed clinical categorization in 6-11% of patients compared to 2D echocardiography.
Why the study?
Does 3D echocardiography alter clinical decision-making compared to 2D echocardiography in patients referred for routine echocardiography?
Observational (n=220)
Yes
Does 3D echocardiography alter clinical decision-making compared to 2D echocardiography in patients referred for routine echocardiography?
Routine 3D echocardiography is feasible in clinical practice and can alter clinical decision-making by reclassifying patients across critical LVEF and LVESV thresholds.
Answers are grounded in this paper and cite their sources.
May refine categorization in select patients; leaves open whether routine 3D use improves prognostic accuracy or outcomes.
OBJECTIVE: To assess the feasibility and potential impact of routine three-dimensional (3D) echocardiographic assessment of left ventricular (LV) ejection fraction and volumes on clinical decision-making. METHODS: Patients referred to three hospital-based echocardiography laboratories underwent 2D echocardiography (2DE) and 3D echocardiography (3DE). Feasibility was assessed in a group of 168 unselected patients and decision-making assessed within an expanded group of 220 patients. The time for acquisition and measurement was obtained. Feasibility was defined by ability to measure LV parameters. The potential of 3DE to alter clinical decisions based on 2DE was evaluated by the ability to identify four clinically relevant measurement thresholds: (1) LV end-systolic volume (LVESV) >50 ml/m(2) (indication for surgery in regurgitant valve disease); (2) LVESV >30 ml/m(2) (prognosis after infarction); (3) LV ejection fraction (LVEF) <35% (indication for implantable defibrillator); and (4) LVEF <40% (indication for heart failure treatment). RESULTS: 3DE was technically feasible in 83% of unselected patients. The additional time for 3D acquisition and measurement was available in 184 patients and was 5.4 (SD 2.0) minutes. The use of 3DE changed categorisation in between 6-11% of patients. Within threshold categories, 3D reallocated 17.5% (11/63) of patients with LVEF <35%, 16.1% (13/81) for LVEF <40%, 12.4% (13/105) for LVESV >30 ml/m(2) and 8.5% (5/59) for LVESV >50 ml/m(2). Most of the impact of 3D was within 10 ml/m(2) of selected volume thresholds (>or=75%) and 10% of EF thresholds (>80%). CONCLUSION: Measurement of LV volumes and EF by 3DE is clinically feasible and has the potential to significantly alter clinical decision-making.
No takes yet. Share an insight, caveat, or question.
Hare et al. (2007) conducted an observational in Patients referred for echocardiography (n=220). 3D echocardiography vs. 2D echocardiography was evaluated on Technical feasibility and change in clinical categorization. Routine 3D echocardiography was technically feasible in 83% of patients and changed clinical categorization in 6-11% of patients compared to 2D echocardiography.
Synapse has enriched 10 related papers. Consider them for comparative context: