Key result
AI-based 12-lead ECG models achieve ~89% pooled sensitivity and specificity for acute coronary syndrome.
Why the study?
The diagnostic accuracy of AI algorithms in detecting ACS using 12-lead ECGs needed systematic evaluation.
Do artificial intelligence-based models applied to 12-lead ECGs improve the diagnostic accuracy (sensitivity and specificity) of acute coronary syndrome detection in adult patients with suspected ACS compared with clinician interpretation or rule-based commercial software?
Systematic Review (n=118,927)
Yes
Do artificial intelligence-based models applied to 12-lead ECGs improve the diagnostic accuracy (sensitivity and specificity) of acute coronary syndrome detection in adult patients with suspected ACS compared with clinician interpretation or rule-based commercial software?
AI models applied to 12-lead ECGs demonstrate high pooled sensitivity (88.9%) and specificity (88.7%) for diagnosing acute coronary syndrome and generally outperform retrospective clinician and rule-based software sensitivity, though clinical adoption is currently limited by high risk of bias, lack of code transparency, and minimal real-time validation.
Answers are grounded in this paper and cite their sources.
May enhance ACS triage in acute settings; extends diagnostic evidence but leaves open prospective validation needs.
Objectives: This systematic review aims to evaluate the diagnostic accuracy of artificial intelligence (AI) algorithms in acute coronary syndrome (ACS) detection using 12-lead electrocardiograms (ECGs). Methods: Adhering to Preferred Reporting Items for Systematic Reviews guidelines, Ovid MEDLINE, Ovid Embase, Cochrane Central, and Cochrane Database of Systematic Reviews were searched up to June 15, 2023. Eligible studies involved adults with suspected ACS and employed AI for 12-lead ECG interpretation. The primary outcomes were sensitivity and specificity, with secondary outcomes including positive predictive value (PPV), negative predictive value (NPV), and accuracy. Risk of bias was evaluated using Prediction model Risk Of Bias Assessment Tool (PROBAST). Results: From 2051 records, 24 studies were included. The sensitivity of AI-based diagnosis for ACS among the 24 studies varied from 68% to 98%, and the specificity varied from 41% to 98%. For subgroup analysis of ST-elevated myocardial infarction/occlusion myocardial infarction, sensitivity ranged from 68% to 97% and specificity from 68% to 99%. AI models outperformed clinicians interpreting ECGs retrospectively without knowledge of outcomes in sensitivity (90% of studies) and PPV (100% of studies), whereas clinicians had better NPV (70% of studies). One study compared AI with real-time emergency department physician interpretations. Three studies reported code availability. Thirty-eight percentage of studies showed a high risk of bias, with 50% showing unclear risk, although applicability concerns were minimal. Conclusion: AI models show high diagnostic accuracy for ACS using 12-lead ECGs, with potential to enhance early diagnosis. However, variability in performance, transparency challenges with limited code availability, a high risk of bias in some studies, and minimal real-time comparisons underscore the necessity for standardized reporting and open-access practices.
No takes yet. Share an insight, caveat, or question.
Fawzy et al. (2025) conducted a systematic review in Suspected Acute Coronary Syndrome (ACS) (n=118,927). Artificial intelligence (ML and DL) algorithms for 12-lead ECG interpretation vs. Clinician interpretation (retrospective or real-time), commercial rule-based ECG software, or other AI models was evaluated on Diagnostic accuracy (sensitivity and specificity) for acute coronary syndrome (ACS) (Pooled sensitivity 88.9% (range 68%-98%); Pooled specificity 88.7% (range 41%-98%), 95% CI 84.1%-92.4%). AI-based 12-lead ECG models demonstrated a pooled sensitivity of 88.9% and pooled specificity of 88.7% for diagnosing acute coronary syndrome across 24 studies.
Synapse has enriched 10 related papers. Consider them for comparative context: