Key result
Three-dimensional echocardiography with a fast-rotating transducer strongly correlated with MRI for measuring LV end-diastolic volume, end-systolic volume, and ejection fraction.
Why the study?
Does a new fast-rotating 3DE transducer with semi-automated border detection accurately measure left ventricular volume and function compared to MRI in cardiac patients?
Observational (n=15)
Does a new fast-rotating 3DE transducer with semi-automated border detection accurately measure left ventricular volume and function compared to MRI in cardiac patients?
A new fast-rotating 3DE transducer with semi-automated border detection provides rapid and accurate measurements of left ventricular volume and function that correlate strongly with cardiac MRI.
Answers are grounded in this paper and cite their sources.
May support rapid LV volumetry in cardiac patients; leaves open whether it can supplant MRI in routine practice.
Measurement of left ventricular (LV) volume and function are the most common clinical referral questions to the echocardiography laboratory. A fast, practical, and accurate method would offer important advantages to obtain this important information. To validate a new practical method for rapid measurement of LV volume and function. We developed a continuous fast-rotating transducer, with second-harmonic capabilities, for three-dimensional echocardiography (3DE). Fifteen cardiac patients underwent both 3DE and magnetic resonance imaging (reference method) on the same day. 3DE image acquisition was performed during a 10-second breath-hold with a frame rate of 100 frames/sec and a rotational speed of 6 rotations/sec. The individual images were postprocessed with Matlab software using multibeat data fusion. Subsequently, with these images, 12 datasets per cardiac cycle were reconstructed, each comprising seven equidistant cross-sectional images for analysis in the new TomTec 4DLV analysis software, which uses a semi-automated border detection (ABD) algorithm. The ABD requires an average analysis time of 15 minutes per patient. A strong correlation was found between LV end-diastolic volume (r = 0.99; y = 0.95x - 1.14 ml; SEE = 6.5 ml), LV end-systolic volume (r = 0.96; y = 0.89x + 7.91 ml; SEE = 7.0 ml), and LV ejection fraction (r = 0.93; y = 0.69x + 13.36; SEE = 2.4%). Inter- and intraobserver agreement for all measurements was good. The fast-rotating transducer with new ABD software is a dedicated tool for rapid and accurate analysis of LV volume and function.
No takes yet. Share an insight, caveat, or question.
Krenning et al. (2006) conducted an observational in Cardiac disease (n=15). Three-dimensional echocardiography with a fast-rotating transducer and semi-automated border detection vs. Magnetic resonance imaging was evaluated on Left ventricular end-diastolic volume, end-systolic volume, and ejection fraction (r = 0.99 for LVEDV, r = 0.96 for LVESV, r = 0.93 for LVEF). Three-dimensional echocardiography with a fast-rotating transducer strongly correlated with MRI for measuring LV end-diastolic volume, end-systolic volume, and ejection fraction.