Key result
Cardiac CT with 3D threshold-based segmentation accurately measured porcine ventricular volumes and detected reduced RVEF 6 months post-TOF surgery.
Why the study?
The accuracy and feasibility of CT for quantifying ventricular volume using semiautomatic 3D threshold-based segmentation in porcine hearts and children with tetralogy of Fallot required investigation.
Does cardiac CT based on semiautomatic 3D threshold-based segmentation accurately quantify ventricular volumetric parameters in porcine heart models and detect postoperative volumetric changes in children with tetralogy of Fallot at 6 months after surgery?
Cohort (n=23)
Radiologist with 20 years' experience blinded to the clinical information of the patients
No
Does cardiac CT based on semiautomatic 3D threshold-based segmentation accurately quantify ventricular volumetric parameters in porcine heart models and detect postoperative volumetric changes in children with tetralogy of Fallot at 6 months after surgery?
Cardiac CT using semiautomatic 3D threshold-based segmentation provides accurate ventricular volume quantification validated against porcine heart casts and enables early detection of subclinical right ventricular systolic function decline in children 6 months after tetralogy of Fallot repair.
Answers are grounded in this paper and cite their sources.
CT segmentation may enable early post-TOF RVEF monitoring; leaves open prospective validation before clinical adoption.
Background To investigate the accuracy and feasibility of CT in quantification of ventricular volume based on semiautomatic three-dimensional (3D) threshold-based segmentation in porcine heart and children with tetralogy of Fallot (TOF). Methods Eight porcine hearts were used in the study. The atria were resected and both ventricles of the eight porcine hearts were filled with solidifiable silica gel and performed CT scanning. The water displacement volume of silica gel casting mould was referred as gold standard of ventricular volume. Results of left and right ventricular volumes measured by CT were compared with reference standard. Twenty-three children diagnosed with TOF were retrospectively included. The ventricular volumetric parameters were assessed by cardiac CT before and 6 months after surgery. Results Left ventricular and right ventricular volumes of porcine hearts measured by CT were highly correlated to casting mould (r=0.845, p=0.008; r=0.933, p=0.001), and there were no statistically significant differences (t=−1.059, p=0.325; t=−1.121, p=0.299). In children with TOF, right ventricular end-systole volumes 6 months after operation were higher than that before surgery, 21.93±4.44 vs 19.80±4.52 mL/m2, p=0.001. Right ventricular ejection fractions 6 months after surgery were lower compared with that before surgery 59.79%±4.26% vs 63.05%±5.04%, p=0.000. Conclusions CT is able to accurately assess ventricular volumetric parameters based on semiautomatic 3D threshold-based segmentation. Both of the right and left ventricular volumetric parameters could be evaluated by CT in children with TOF.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2019) conducted a cohort in Tetralogy of Fallot (TOF) (n=23). Cardiac CT quantification based on semiautomatic 3D threshold-based segmentation (6 months post-corrective TOF surgery) vs. Preoperative cardiac CT assessment (and water displacement volume of silica gel casting mould in 8 porcine hearts) was evaluated on Right ventricular ejection fraction (RVEF, %) at 6 months after surgery vs before surgery (p=<0.001). Cardiac CT with 3D threshold-based segmentation accurately measured porcine ventricular volumes and detected reduced RVEF 6 months post-TOF surgery.
Synapse has enriched 10 related papers. Consider them for comparative context: