Key result
Low-intensity anticoagulation (target INR 1.5-2.5) in Chinese patients after heart valve replacement showed low anticoagulation-related morbidity (0.67% Pty) and mortality (0.15% Pty).
Why the study?
Is a low-intensity anticoagulation strategy with warfarin (target INR 1.5-2.5) safe and effective for Chinese patients undergoing heart valve replacement?
Cohort (n=46,292)
Yes
Is a low-intensity anticoagulation strategy with warfarin (target INR 1.5-2.5) safe and effective for Chinese patients undergoing heart valve replacement?
A low-intensity anticoagulation strategy with a target INR of 1.5-2.5 is safe and effective for Chinese patients following heart valve replacement, demonstrating low rates of bleeding and thromboembolic complications.
Low-intensity anticoagulation was associated with low complications in Chinese valve patients; hypothesis-generating, needs RCTs before practice change.
OBJECTIVE: To investigate the optimal anticoagulation methods and monitoring strategy for Chinese patients undergoing heart valve replacement, which is potentially quite different from western populations. METHODS: In this multicenter prospective cohort study, the anticoagulation and monitoring strategy data was acquired from 25 773 in-hospital patients in 35 medical centers and 20 519 patients in outpatient clinic in 11 medical centers from January 1st, 2011 to December 31th, 2015. RESULTS: As for in-hospital patients, mean age of study population was (48.6±11.2) years old; main etiology of valve pathology was rheumatic (87.5%) origin among study cohort; 94.8% of study population received mechanical valve implantation; international normalized ratio (INR) monitoring (in all the study centers) and low-intensity anticoagulation strategy (31 hospitals chose target INR range of 1.5-2.5, and actual values of INR among 89.2% of 100 069 in-hospital monitoring samples were 1.5-2.5), with mean actual INR values of 1.84±0.53, and warfarin dosage of (2.82±0.93) mg/d were widely adopted among the study centers; strategies of in-hospital warfarin administration were similar in all the study centers; complication rates of low-intensity anticoagulation strategy were low in severe hemorrhage (0.02%), thrombosis (0.05%), and thromboembolism (0.05%) events, without anticoagulation-related death.As for 18 974 outpatient clinic patients, the follow-up rate was 92.47%, with a total of 30 012 patient-years (Pty). Anticoagulation-related morbidity and mortality rates were 0.67% and 0.15% Pty; major hemorrhage morbidity and mortality rates were 0.25% and 0.13% Pty; thromboembolism morbidity and mortality rates were 0.45% and 0.03% Pty.The mean dosage of warfarin daily dosage was (2.85±1.23) mg/d and INR value was 1.82±0.57.No significant regional difference in the intensity of anticoagulation therapy was noted during the study. CONCLUSIONS: INR can be used as a normalized indicator for intensity of anticoagulation therapy in China.The optimal anticoagulation intensity with INR range from 1.5 to 2.5 is safe and effective for Chinese patients with heart valve replacement, and there is no significant regional difference in the intensity of anticoagulation therapy.
No takes yet. Share an insight, caveat, or question.
Li et al. (2016) conducted a cohort in heart valve replacement (n=46,292). Low-intensity anticoagulation therapy (target INR 1.5-2.5) was evaluated on Anticoagulation-related morbidity. Low-intensity anticoagulation (target INR 1.5-2.5) in Chinese patients after heart valve replacement showed low anticoagulation-related morbidity (0.67% Pty) and mortality (0.15% Pty).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: