Key result
Periarticular infiltration of ketorolac resulted in a higher clearance rate (4.50 vs 1.40 L/h) and lower peak plasma concentration for the S(-) enantiomer compared to the R(+) enantiomer.
Why the study?
What are the pharmacokinetic properties of S (-) and R (+) enantiomers of periarticular ketorolac in adult patients undergoing total hip or knee replacement surgery?
Observational (n=18)
What are the pharmacokinetic properties of S (-) and R (+) enantiomers of periarticular ketorolac in adult patients undergoing total hip or knee replacement surgery?
S (-) ketorolac has a higher clearance rate and lower peak plasma concentration compared to R (+) ketorolac when administered via periarticular infiltration in joint replacement surgery.
Should not alter current periarticular ketorolac practice; leaves open whether enantiomer differences affect efficacy or safety.
BACKGROUND: Ketorolac tromethamine has been used for joint infiltration by the orthopedic surgeons as a part of postoperative multimodal analgesia. The objective of this study is to investigate the pharmacokinetic properties of S (-) and R (+) enantiomers of ketorolac in adult patients undergoing total hip (THA) and knee arthroplasty (TKA). METHODS: Adult patients with normal preoperative renal function received a periarticular infiltration of 30 mg of ketorolac tromethamine along with 100 mL of 0.2% ropivacaine and 1 mg of epinephrine at the end of their THA or TKA surgery. Blood samples were taken from a venous cannula at various time points after infiltration. Pharmacokinetic modeling was performed using PMetrics 1.5.0. RESULTS: From 18 participants, 104 samples were analyzed. The peak plasma concentration for S (-) ketorolac was found to be lower than that of R (+) ketorolac, for both THA (0.19-1.22 mg/L vs 0.39-1.63 mg/L, respectively) and TKA (0.28-0.60 mg/L vs 0.48-0.88 mg/L, respectively). The clearance of the S (-) ketorolac enantiomer was higher than R (+) ketorolac (4.50 ± 2.27 vs 1.40 ± 0.694 L/h, respectively). CONCLUSIONS: Our study demonstrates that with periarticular infiltration, S (-) ketorolac was observed to have increased clearance rate and highly variable volume of distribution and lower peak plasma concentration compared to R (+) ketorolac.
No takes yet. Share an insight, caveat, or question.
Gurunathan et al. (2018) conducted an observational in Total hip or total knee replacement surgery (n=18). Periarticular infiltration of ketorolac tromethamine was evaluated on Pharmacokinetic properties (peak plasma concentration and clearance) of S(-) and R(+) enantiomers of ketorolac. Periarticular infiltration of ketorolac resulted in a higher clearance rate (4.50 vs 1.40 L/h) and lower peak plasma concentration for the S(-) enantiomer compared to the R(+) enantiomer.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: