Key result
Modified QT formula reliably estimates QTc in bundle branch block, especially with Hodges correction.
Why the study?
Estimating the true repolarization time is challenging in the presence of bundle-branch block because QRS prolongation widens the QT interval, and physicians are less familiar with interpreting the recommended JT interval.
How can the QT interval be accurately estimated in patients with bundle branch block?
How can the QT interval be accurately estimated in patients with bundle branch block?
A simple formula (QTm = QTBBB - 50% QRSBBB) allows for practical estimation of the modified QT interval in patients with bundle branch block, offering an alternative to JT interval measurement.
Answers are grounded in this paper and cite their sources.
May support QTc estimation in bundle branch block; leaves open prospective validation before clinical adoption.
Proper measurement of the QT interval on the 12-lead body-surface ECG is challenging in daily practice. Even more difficult is its correct estimation in the presence of repolarization abnormalities, arrhythmias or bundle-branch blocks (BBB). The QT interval results from two parts of the ECG: (1) the QRS complex, describing the excitation of the ventricles and (2) the JT interval, describing the repolarisation of the ventricles. Prolongation of the QRS width – like in the presence of BBB – entails prolongation of the QT interval, making the estimation of the true repolarisation time challenging. The US recommendations for the standardization and interpretation of the ECG suggest focusing on the JT interval in presence of BBB. However, in clinical practice physicians have become more familiar with the interpretation of QT-interval measurements than with the interpretation of the JT Interval. In the last decade, a simple formula for the estimation of the “modified QT interval” in the presence of left or right BBB has been developed and evaluated. In this formula, the modified QT interval is calculated by subtracting 50% of the length of the BBB-QRS from the measured QT interval (QTm = QTBBB − 50% QRSBBB). Subsequently, rate-correction formula should be applied as usual. In this review, we discuss the determination of the QT-interval in the presence of BBB and summarize the origin and application of the modified QT-interval formula.
No takes yet. Share an insight, caveat, or question.
Bogossian et al. (2020) conducted a review in Bundle branch block (LBBB and RBBB). Modified QT-interval formula (QTm = QTBBB - 50% QRSBBB) vs. Intrinsic narrow-QRS QTc interval or alternative QT-correction formulas was evaluated on Estimation of true repolarization time (QTc interval) in the presence of bundle branch block. The modified QT formula, ideally paired with Hodges rate correction, reliably estimates QTc in patients with left or right bundle branch block.