Key result
Device and surgical ASD closure were associated with abnormal LA and RA strain values compared to controls at 1 to 5 years post-procedure, with surgical closure showing worse RA reservoir function.
Why the study?
Data comparing right and left atrial functions between surgical and percutaneous device ASD closure at follow-up durations longer than 1 year were lacking.
Does percutaneous device ASD closure compared to surgical ASD closure result in different right and left atrial functions at 1 to 5 years follow-up?
Observational (n=90)
Does percutaneous device ASD closure compared to surgical ASD closure result in different right and left atrial functions at 1 to 5 years follow-up?
Both surgical and device ASD closure are associated with abnormal atrial strain parameters at midterm follow-up compared to controls, with surgical closure showing worse RA reservoir function than device closure.
Abnormal atrial strain after ASD closure should not change practice; leaves open need for prospective outcome studies.
OBJECTIVES: The available literature lacks data on the comparison of the functions of the right atrium (RA) and left atrium (LA) between surgical atrial septal defect (ASD) closure and percutaneous device ASD closure at follow-up durations of longer than 1 year. We sought to evaluate the RA and LA functions in patients who underwent surgical or device ASD closure between 1 and 5 years postprocedurally. METHODS: The study population included 30 patients who underwent device ASD closure and 30 who underwent surgical ASD closure, who were matched for the procedural time, age, and sex, in addition to 30 control participants. The RA and LA functions were evaluated with 2-dimensional speckle-tracking echocardiography. RESULTS: The LA systolic and early diastolic strain and strain rate values and the RA early diastolic strain rate in the device closure group were more likely to be abnormal than in the control group. The RA systolic and late diastolic strain and strain rate values, the RA early diastolic strain rate, and the LA early diastolic strain in the surgical closure group were more likely to be abnormal than in the control group. The RA systolic strain and strain rate in the surgical closure group were more likely to be abnormal than in the device closure group. CONCLUSIONS: The LA reservoir and conduit functions and the RA contraction function in the patients who underwent device ASD closure and all of the RA functions and the LA conduit function in the patients who underwent surgical ASD closure were more likely to be abnormal than those in the control participants. The RA reservoir function in the surgical closure group was more likely to be abnormal than that in the device closure group.
No takes yet. Share an insight, caveat, or question.
Hajizeinali et al. (2018) conducted an observational in Atrial septal defect (n=90). Device or surgical atrial septal defect closure vs. Healthy controls was evaluated on Right and left atrial functions (strain and strain rate) evaluated with 2-dimensional speckle-tracking echocardiography. Device and surgical ASD closure were associated with abnormal LA and RA strain values compared to controls at 1 to 5 years post-procedure, with surgical closure showing worse RA reservoir function.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: