Key result
Transfemoral transcatheter aortic valve replacement using an Edwards SAPIEN XT valve was successfully performed in an 81-year-old male with an aneurysmal membranous interventricular septum.
Case Report (n=1)
No
This case demonstrates the feasibility of transfemoral TAVR in a patient with an aneurysmal membranous interventricular septum extending into the left ventricular outflow tract.
Supports TAVR feasibility in rare perimembranous septal aneurysm; leaves open need for prospective safety data.
We report a challenging case of a 81-year-old male with history of severe calcific aortic valve stenosis and aneurysmal membranous interventricular septum. The presence of anomalies in the sub-annular area can lead to valve malpositioning and its consequences. transcatheter aortic valve implantation (TAVR) in patients with aneurysm of the perimembranous interventricular septum extending into the left ventricular outflow tract has not been previously reported. This case describes a successful transfemoral TAVR with an Edwards SAPIEN XT valve (Edwards Lifesciences, Irvine, CA, United States) with such anomaly.
No takes yet. Share an insight, caveat, or question.
Banga et al. (2018) conducted a case report in Severe calcific aortic valve stenosis and aneurysmal membranous interventricular septum (n=1). Transfemoral TAVR with an Edwards SAPIEN XT valve was evaluated on Procedural success. Transfemoral transcatheter aortic valve replacement using an Edwards SAPIEN XT valve was successfully performed in an 81-year-old male with an aneurysmal membranous interventricular septum.