Key result
Repositionable self-expanding TAVR achieves successful positioning without conduction disturbances in a membranous septal aneurysm.
Why the study?
Reports of transcatheter aortic valve replacement in patients with membranous septal aneurysm remain limited despite its not rare occurrence with modern imaging.
Can a repositionable intra-annular self-expanding valve be safely and effectively deployed for TAVR in a patient with severe aortic stenosis and a membranous septal aneurysm?
Case Report (n=1)
Can a repositionable intra-annular self-expanding valve be safely and effectively deployed for TAVR in a patient with severe aortic stenosis and a membranous septal aneurysm?
A repositionable intra-annular self-expanding valve can be a feasible TAVR strategy in patients with severe aortic stenosis complicated by a membranous septal aneurysm to optimize positioning and preserve coronary access.
Answers are grounded in this paper and cite their sources.
Supports feasibility of repositionable valve TAVR in membranous septal aneurysm with low coronary height; leaves open generalizability and safety in larger cohorts.
An 83-year-old woman presented with dyspnea on exertion and was diagnosed with severe aortic stenosis. Preprocedural multidetector computed tomography revealed a membranous septal aneurysm (MSA) beneath the right–noncoronary commissure, with borderline annular dimensions. Coronary height was low, particularly in the left coronary artery (7.5 mm), and moderate coronary artery disease was also present. Given the uncertainty in annular sizing caused by the anatomical complexity and the more certain preservation of coronary access, transcatheter aortic valve replacement (TAVR) was performed using a repositionable intra-annular self-expanding valve. Balloon aortic valvuloplasty was cautiously performed, and a 25-mm valve was implanted using a cusp-overlap technique and multiple fluoroscopic projections with controlled pacing. Initial deployment was suboptimal; however, a recapturable system enabled appropriate positioning with mild-to-moderate paravalvular leakage (PVL), without conduction disturbances. Follow-up transthoracic echocardiography demonstrated favorable valve function without PVL progression. This case highlights the importance of careful preprocedural assessment and tailored procedural strategy in TAVR for patients with MSA. Learning objective We highlight practical considerations for transcatheter aortic valve replacement (TAVR) in patients with membranous septal aneurysm. This abnormal structure is not particularly rare with modern non-invasive imaging; however, reports of TAVR in this setting remain limited. This case emphasizes the importance of meticulous preprocedural imaging assessment and the advantages of a repositionable intra-annular self-expanding valve for optimal implantation position, preservation of future coronary access, and successful transcatheter therapy despite calcified lower extremity arteries.
No takes yet. Share an insight, caveat, or question.
Hosokawa et al. (2026) conducted a case report in Severe aortic stenosis with membranous septal aneurysm (n=1). Transcatheter aortic valve replacement (TAVR) with a repositionable intra-annular self-expanding valve was evaluated on Procedural success, valve position, paravalvular leakage, and conduction disturbances. Transcatheter aortic valve replacement using a repositionable intra-annular self-expanding valve achieved appropriate positioning without conduction disturbances in a patient with a membranous septal aneurysm.
Synapse has enriched 10 related papers. Consider them for comparative context: