Power quality problem such as unbalanced voltage have adverse effects on the satisfactory performance of three phase induction motors which are the main work horses in many industrial, commercial and residential applications. The new models of three phase induction motor and adjustable speed drives are highly susceptible to unbalance voltage. Detecting whether the supplied voltage to these machine is balanced or unbalance is very vital, if the service life and motor efficiency will be maintained for a reasonably numbers of years. This paper applied Artificial Neutral Network for detection of voltage unbalance. ANN was satisfactorily trained with 100 samples of real-time voltage readings supplied to three phase induction motors. The collected data were the fed to the trained ANN for classification. The results of the analysis showed that 26.25% were detected to be balanced voltage while 73.75% were tagged unbalanced. It was observed that Mean Squared Error (MSE) was found to be 0.084321, Root Mean Squared Error (RMSE) was found to be 0.781885 and percentage accuracy was 100% for balanced and unbalanced voltage.
No takes yet. Share an insight, caveat, or question.
Okelola et al. (2018) studied this question.