Key result
Computational fluid dynamics and signal processing of flow through arterial stenosis identified break frequencies ranging from 80 to 220 Hz correlated to eddies generated within the fluctuating zone.
Why the study?
For the early detection of atherosclerosis, exploring new, effective noninvasive diagnosis techniques is imperative to reduce associated treatment costs and mortality rates.
Answers are grounded in this paper and cite their sources.
Computational fluid dynamics and signal processing can localize high-energy mechano-acoustic sources in arterial stenosis, potentially aiding in the early noninvasive detection of atherosclerosis.
For the early detection of atherosclerosis, it is imperative to explore the capabilities of new, effective noninvasive diagnosis techniques to significantly reduce the associated treatment costs and mortality rates. In this study, a multifaceted comprehensive approach involving advanced computational fluid dynamics combined with signal processing techniques was exploited to investigate the highly turbulent fluctuating flow through arterial stenosis. The focus was on localizing high-energy mechano-acoustic source potential to transmit to the epidermal surface. The flow analysis results showed the existence of turbulent pressure fluctuations inside the stenosis and in the post-stenotic region. After analyzing the turbulent kinetic energy and pressure fluctuations on the flow centerline and the vessel wall, the point of maximum excitation in the flow was observed around two diameters downstream of the stenosis within the fluctuating zone. It was also found that the concentration of pressure fluctuation closer to the wall was higher inside the stenosis compared to the post-stenotic region. Additionally, the visualization of the most energetic proper orthogonal decomposition (POD) mode and spectral decomposition of the flow indicated that the break frequencies ranged from 80 to 220 Hz and were correlated to the eddies generated within these regions.
No takes yet. Share an insight, caveat, or question.
Khalili et al. (2021) studied Arterial stenosis. Computational fluid dynamics and signal processing was evaluated on Localization of high-energy mechano-acoustic source potential and break frequencies. Computational fluid dynamics and signal processing of flow through arterial stenosis identified break frequencies ranging from 80 to 220 Hz correlated to eddies generated within the fluctuating zone.
Synapse has enriched 10 related papers. Consider them for comparative context: