Key result
A reduction in the high frequency component ratio (HFCR pre-post) of 1.0% during ablation differentiated patients with and without ventricular arrhythmia recurrence.
Why the study?
Does the reduction in high frequency component ratio (HFCR pre-post) predict recurrence of ventricular arrhythmias after successful ablation in the aortic root?
Cohort (n=56)
Does the reduction in high frequency component ratio (HFCR pre-post) predict recurrence of ventricular arrhythmias after successful ablation in the aortic root?
Quantifying near-field activation changes using spectrum analysis (HFCR pre-post) during ablation can accurately predict recurrence of ventricular arrhythmias from the aortic root.
Answers are grounded in this paper and cite their sources.
HFCR pre-post may aid post-ablation risk stratification for aortic root VA; hypothesis-generating and requires prospective validation before clinical adoption.
OBJECTIVE: The mechanism underlying recurrence after successful ablation of ventricular arrhythmias (VAs) was unclear. Spectrum analysis can help to identify near-field activation. The purpose of this study was to quantify the changes of near-field activation in response to ablation at the VAs origin in the aortic root (AR-VAs) and to assess its relationship with late ablation outcome. METHODS AND RESULTS: Patients who underwent acutely successful ablation for AR-VAs were analysed. Ventricular electrograms acquired before and after ablation at VAs origin were subjected to spectrum analysis. The area under the curve of the high frequency component (HFC, 50-200 Hz) and the low frequency component (LFC, 0-50 Hz) was measured. The proportion of HFC to the frequency spectrum of 0-200 Hz was defined as the HFC ratio (HFCR). The reduction of HFC and HFCR in response to ablation was defined as HFC pre-post and HFCR pre-post, respectively. Documentation of VAs with the same morphology after an acute successful procedure was defined as recurrence. Fifty-six patients were analysed, and VAs recurred in 17 patients. HFCR pre-post, HFC pre-post, and HFC pre-ablation were significantly higher in patients without recurrence. And HFCR pre-post has the highest predictive value (area under the receiver-operating characteristic curve: 0.975). A HFCR pre-post of 1.0% differentiated two groups (sensitivity = 84.6%, specificity = 100%). Higher HFCR pre-post was correlated with shorter VAs termination time (correlation coefficient = -0.399, p = .009). CONCLUSIONS: HFCR pre-post can quantify the near-field activation change during ablation. Incomplete destruction to the VAs foci could underlie recurrence after successful ablation.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2017) conducted a cohort in Ventricular arrhythmias from the aortic root (n=56). Reduction of high frequency component ratio (HFCR pre-post) was evaluated on Recurrence of ventricular arrhythmias with the same morphology (AUC 0.975). A reduction in the high frequency component ratio (HFCR pre-post) of 1.0% during ablation differentiated patients with and without ventricular arrhythmia recurrence.
Synapse has enriched 10 related papers. Consider them for comparative context: