Key result
Exposure to hyperbaric environments increased parasympathetic response with atmospheric pressure and decreased heart rate and sympathetic markers over time, with PPG and ECG yielding similar results.
Why the study?
Does exposure to hyperbaric environments alter the Autonomic Nervous System response as measured by ECG and PPG signals?
Observational (n=26)
No
Does exposure to hyperbaric environments alter the Autonomic Nervous System response as measured by ECG and PPG signals?
ECG and PPG signals can effectively monitor autonomic nervous system changes, showing increased parasympathetic and decreased sympathetic activity in hyperbaric environments.
Answers are grounded in this paper and cite their sources.
Caution advised in hyperbaric applications; leaves open clinical relevance of ANS metrics pending larger prospective studies.
The main aim of this paper was to characterize the Autonomic Nervous System response in hyperbaric environments using electrocardiogram (ECG) and pulse-photoplethysmogram (PPG) signals. To that end, 26 subjects were introduced into a hyperbaric chamber and five stages with different atmospheric pressures (1 atm; descent to 3 and 5 atm; ascent to 3 and 1 atm) were recorded. Respiratory information was extracted from the ECG and PPG signals and a combined respiratory rate was studied. This information was also used to analyze Heart Rate Variability (HRV) and Pulse Rate Variability (PRV). The database was cleaned by eliminating those cases where the respiratory rate dropped into the low frequency band (LF: 0.04-0.15 Hz) and those in which there was a discrepancy between the respiratory rates estimated using the ECG and PPG signals. Classical temporal and frequency indices were calculated in such cases. The ECG results showed a time-related dependency, with the heart rate and sympathetic markers (normalized power in LF and LF/HF ratio) decreasing as more time was spent inside the hyperbaric environment. A dependence between the atmospheric pressure and the parasympathetic response, as reflected in the high-frequency band power (HF: 0.15-0.40 Hz), was also found, with power increasing with atmospheric pressure. The combined respiratory rate also reached a maximum in the deepest stage; thus, highlighting a significant difference between this stage and the first one. The PPG data gave similar findings and also allowed the oxygen saturation to be computed; therefore, we propose the use of this signal for future studies in hyperbaric environments.
No takes yet. Share an insight, caveat, or question.
Hernando et al. (2018) conducted an observational in Healthy subjects (n=26). Hyperbaric environment vs. 1 atm (sea level) was evaluated on Autonomic Nervous System (ANS) response (HRV, PRV, respiratory rate). Exposure to hyperbaric environments increased parasympathetic response with atmospheric pressure and decreased heart rate and sympathetic markers over time, with PPG and ECG yielding similar results.
Synapse has enriched 10 related papers. Consider them for comparative context: