Answers are grounded in this paper and cite their sources.
[Purpose] We investigated the effect of low-intensity pulsed ultrasound and cryotherapy on joint function recovery and C-reactive protein (CRP) levels of patients with total knee replacement. [Subjects] Forty-six patients with total knee replacement were recruited and allocated to either low-intensity pulsed ultrasound therapy (n=15), cryotherapy (n=15), or a combination of both (n=16). Therapy was administered once a day, 5 times a week for 3 weeks. To determine functional joint recovery and reduction of inflammation, changes in the Korean Western Ontario and McMaster Universities Arthritis Index (K-WOMAC), range of motion (ROM), and CRP were assessed postsurgically and four times over a 3-week period. Using one-way analysis of variance (ANOVA), homogeneity tests were performed based on participants' general characteristics. To recognize changes in time-variant K-WOMAC, ROM, and CRP values between groups, repeated measures ANOVA was performed, and Tukey's test was used for post-test analysis. Values at α=0.05 were considered significant. [Results] We found a difference between groups and times, and the group that received the combined therapies showed greater changes in outcomes than the group that received low-intensity pulsed ultrasound therapy alone. [Conclusion] Applying both low-intensity pulsed ultrasound and cryotherapy can relieve inflammation and enhance joint function in patients who undergo total knee replacement.
No takes yet. Share an insight, caveat, or question.
Kang et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: