Key result
Methoxyacetylation with LC-TIMS-qTOF/MS achieves highly precise and accurate quantification of angiotensin peptides.
Why the study?
Quantification of key circulating renin-angiotensin system effectors, including Ang I, Ang (1-9), Ang II, Ang (1-7), and Ang A, is essential for understanding blood pressure regulation.
The developed LC-TIMS-qTOF/MS method provides a highly sensitive and selective platform for multiplexed quantification of angiotensin metabolites to investigate renin-angiotensin system dynamics.
Quantification of key effectors in the circulating renin-angiotensin system (RAS), including angiotensin (Ang) I, Ang (1-9), Ang II, Ang (1-7), and Ang A, is essential for understanding RAS-mediated blood pressure regulation. Herein, we present a highly sensitive and selective analytical method based on methoxyacetylation coupled with liquid chromatography-trapped ion mobility spectrometry-quadrupole time-of-flight mass spectrometry (LC-TIMS-qTOF/MS) operated in parallel reaction monitoring-parallel accumulation serial fragmentation (prm-PASEF) mode. Methoxyacetylation using an NHS ester reagent modulated protonation and fragmentation behavior, resulting in enhanced signal intensity and more concentrated product-ion formation. The TIMS parameters were optimized to achieve maximal sensitivity, with an inverse reduced mobility (1/ k 0 ) range of 0.7–1.1 cm 2 ·V -1 ·s -1 and accumulation and ramp times of 150 ms. Under these conditions, the method exhibited excellent analytical performance, with limits of detection ranging from 0.6 to 3.4 fmol/mL, precision below 9.3% (CV), and accuracy within 95.1–105.8%. Using [ 13 C 5 , 15 N]-labeled Ang II as an internal standard, all five target angiotensin peptides were successfully quantified from 100 μL of Sprague-Dawley rat plasma. The developed method provides a robust and sensitive platform for multiplexed quantification of angiotensin metabolites and enables detailed investigation of RAS dynamics in biological systems.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question. Methoxyacetylation coupled with LC-TIMS-qTOF/MS was evaluated on Limits of detection, precision, and accuracy. Methoxyacetylation coupled with LC-TIMS-qTOF/MS achieved limits of detection of 0.6 to 3.4 fmol/mL, precision below 9.3%, and accuracy within 95.1–105.8% for quantifying angiotensin peptides.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: