Pseudo spin valve cells with critical dimension 0.15 /spl mu/m were fabricated using e-beam lithography and exercised with an externally applied magnetic field. Data indicate that bit end shaping is important for cell stability. At such small critical dimensions, the field required to write a cell is large, approximately 180 Oe for cells with 60 /spl Aring/ and 80 /spl Aring/ thick magnetic layers. A single-domain model was used to predict switching thresholds for various word field rise times. Results indicate that significant lowering of the write field thresholds may occur for rise times less than about 2 ns.
No takes yet. Share an insight, caveat, or question.
Everitt et al. (1998) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: